VBC 200-3 Water heating batt

Art. no.: 9841

• 3-rows battery
• Removable cover for cleaning the unit.
• The water-heating battery can be installed in a horizontal or a vertical duct with optional direction of airflow.
• Casing made of magnesium/zinc-treated steel sheet, heat transmission element with copper tubes and aluminium fins.
• Water-heating battery for heating air in ventilation systems with circular ducts.
• Max operating temperature 150 °C
• Max operating pressure 1,0 MPa (10Bar. Tested at 16Bar.)

Technical parameters

Dimensions and weights
Duct dimension; Circular, inlet 200 mm
Duct dimension; Circular, outlet 200 mm
Weight 7.6 kg
Others
Duct cooler/heater Heater coil, water
Duct connection type Circular
Images Performance - VBC 200-3 Water heating batt - Systemair

 

Air flow (m3/s)

Pressure drop (Pa)

ΔT air at T water 60/40, ˚C

Water flow rate (l/s)

Water speed (m/s)

Pressure drop (kPa)

Power (kW)

ΔT air at T water 90/70, ˚C

Water flow rate (l/s)

Water speed (m/s)

Pressure drop (kPa)

Power (kW)

Inlet air temp 0˚C

VBC 100-3 VBC 125-3 VBC 160-3 VBC 200-3 VBC 250-3 VBC 315-3 VBC 400-3

0,04

0,06

0,1

0,15

0,25

0,39

0,63

39

17,2

41

29

31,2

35

36,3

25,9

33,4

29,3

30,7

30,5

30,2

30,3

0,02

0,03

0,05

0,07

0,12

0,19

0,3

0,24

0,47

0,68

0,54

0,59

0,69

0,74

0,85

5,33

11

5,36

6,23

8,28

10,10

1,35

2,6

3,8

6

9,93

15,3

24,74

47,4

56,2

49,7

52,1

51,6

51

50,8

0,03

0,05

0,08

0,13

0,21

0,32

0,51

0,45

0,8

1,17

0,92

1,02

1,17

1,26

2,65

14

29,5

14,1

16,2

21,4

26,1

2,46

4,38

6,46

10,17

16,8

25,87

41,6

Images Dimensions - VBC 200-3 Water heating batt - Systemair
ØD B H Ødy F G K L

200

398

330

22

250

40

276

356

AQUA 24TF Heat Regulator - Systemair
Art. no.: 5136
AQUA 24TF Heat Regulator .
Optigo OP 10 - Systemair
Art. no.: 7282
Optigo OP 10 .
TG-A1/PT1000 Surface sensor - Systemair
Art. no.: 7284
TG-A1/PT1000 Surface sensor

.

.
TG-A130 Surface sensor 0-30°C - Systemair
Art. no.: 5159
TG-A130 Surface sensor 0-30°C .
TG-K330 Duct Sensor 0-30°C - Systemair
Art. no.: 5160
TG-K330 Duct Sensor 0-30°C .
TG-K360 Duct sensor 0-60°C - Systemair
Art. no.: 4846
TG-K360 Duct sensor 0-60°C

for heating regulator HRG

.
Argus-RC-DO Room Controller - Systemair
Art. no.: 2916
Argus-RC-DO Room Controller

Stand alone room controllers 24/ 0-10V

.
Optigo OP 10-230 - Systemair
Art. no.: 7283
Optigo OP 10-230 .
Optigo OP 5 - Systemair
Art. no.: 13891
Optigo OP 5 .
RVAZ4 24A Actuator 0-10V - Systemair
Art. no.: 9862
RVAZ4 24A Actuator 0-10V .
RVAZ4-24 Actuator 3points - Systemair
Art. no.: 9798
RVAZ4-24 Actuator 3points

24 V AC

.
ZTR 15-1,0 valve 3-way - Systemair
Art. no.: 9672
ZTR 15-1,0 valve 3-way

DN 15 Kvs 1,0

.
ZTV 15-1,0 2-way valve - Systemair
Art. no.: 9823
ZTV 15-1,0 2-way valve

DN 15 Kvs 1,0

.