Simbolo ECOM

K 315 sileo

Ventilatore centrifugo circolare in linea

Numero articolo: 251015

• Speed-controllable
• Quiet-running
• Increased efficiency
• Integral thermal contacts
• Can be installed in any position
• Can be installed outdoors
• Maintenance-free and reliable

The K Sileo series is designed for installation in ducts. All K-fans have a minimum 25 mm long spigot connections.

The fans have backward-curved blades and external rotor motors. To simplify the installation the K Sileo fan has a fixing bracket together with screws for mounting the bracket included as standard. The FK mounting clamp facilitates easy installation and removal, and prevents the transfer of vibration to the duct. The fans can be speed-controlled via a stepless thyristor or a 5-step transformer.

To protect the motor from overheating the fan has integral thermal contacts with manual reset.

The casing is manufactured from galvanised sheet steel and folded which gives the fan a close to air tight casing. Duct connected outdoor and wet room applications of the fan are possible due to the air tight casing

Eco design

Prodotto
Nome commerciale Systemair
Nome prodotto K 315 sileo
Eco design
In accordo a ERP 2018
Categoria unità NRVU
Trasmissione MSD o VSD esterno
tipo unità UVU
Tipo recupero di calore Nessuno
Rapporto temperatura (UVU) Non disponibile
Qv nom 0,21 m³/s
P nom 0,22 kW
Pressione stat. nominale 417 Pa
Rendimento ventilatore 40 %
Trafilamento esterno 0 %
Livello potenza sonora LWA 44 dB(A)

Parametri tecnici

Dati nominali
Voltaggio (nominale) 230 V
Frequenza 50 Hz
Fasi 1~
Potenza in entrata 217 W
Corrente in entrata 0,95 A
Velocità rotazione girante 2.719 rpm
Portata aria max 1.256 m³/h
Capacità del condensatore 5 µF
Temperatura aria trasportata max 70 °C
Temperatura max aria trasportata, sotto regolazione 70 °C
Dati acustici
Livello pressione sonora a 3 m (20m² Sabine) 43 dB(A)
Protezione/Classificazione
Classe di protezione, motore IP44
Classe d'isolamento F
Dati in accordo a ERP
Pronto ErP ErP 2016; ErP 2018
Dimensioni e pesi
Dimensione condotto; Circolare, immissione 315 mm
Dimensione condotto; Circolare, espulsione 315 mm
Peso 6,6 kg
Altri
Tipo connessione condotto Circolare
Tipo motore AC
Images Dimensions - K 315 sileo - Systemair
øA øB C D E F

314

408

32.5

160.5

27

220

RE 1,5 - Systemair
Numero articolo: 5000
RE 1,5

Regolatore manuale a 5 velocità

.
REE 2 - Systemair
Numero articolo: 5316
REE 2

Regolatore di velocità (Tristore) monofase.

.
REU 1.5 - Systemair
Numero articolo: 5004
REU 1.5

Regolatore manuale a 5 velocità

.
SG 315 - Systemair
Numero articolo: 5611
SG 315

Griglia circolare di protezione

.
VKK-315 - Systemair
Numero articolo: 1628
VKK-315

Serranda di sovrapressione

.
C04D - Systemair
Numero articolo: 5630
C04D .
CO2RT-R-D - Systemair
Numero articolo: 6993
CO2RT-R-D

Sensore di CO2 da interno UR 0-75% IP30

.
DTV500A - Systemair
Numero articolo: 96807
DTV500A

Pressostato differenziale 0-500 Pa IP54

.
IR24-P - Systemair
Numero articolo: 6995
IR24-P

Rilebatore di prsenza a infrarossi da interno IP40

.
RT 0-30 - Systemair
Numero articolo: 5151
RT 0-30

Termostato ambiente IP30

.
TUNE-R-315-B - Systemair
Numero articolo: 311905
TUNE-R-315-B

Serranda di regolazione circolare con comando integrato

.
CB 315-12,0 400V/3 - Systemair
Numero articolo: 5387
CB 315-12,0 400V/3

Batteria elettrica circolari

.
CB 315-3,0 230V/1 - Systemair
Numero articolo: 5386
CB 315-3,0 230V/1

Batteria elettrica circolari

.
CB 315-9,0 400V/3 - Systemair
Numero articolo: 5375
CB 315-9,0 400V/3

Batteria elettrica circolari

.
CBM 315-9,0 400V/3 - Systemair
Numero articolo: 5485
CBM 315-9,0 400V/3

Batteria elettrica circolari con controllo integrato.

.
CBMF 315-9,0 400V/3 Duct heate - Systemair
Numero articolo: 12354
CBMF 315-9,0 400V/3 Duct heate .
CWK 315-3-2,5 - Systemair
Numero articolo: 30025
CWK 315-3-2,5

Batteria ad acqua calda/fredda con imbocchi circolari

.
FFR 315 - Systemair
Numero articolo: 1779
FFR 315

Cassetta portafiltro con prese DoP (filtro non compreso)

.
FGR 315 - Systemair
Numero articolo: 1818
FGR 315

Cassetta portafiltro con filtro G3 compreso

.
FK 315 - Systemair
Numero articolo: 1613
FK 315

Collare a sgancio rapido

.
LDC 315-900 - Systemair
Numero articolo: 5197
LDC 315-900

Silenziatore circolare con attacco a baionetta

.
RSK-315 - Systemair
Numero articolo: 5604
RSK-315

Serranda automatica di non ritorno

.
VBC 315-2 - Systemair
Numero articolo: 5461
VBC 315-2

Batteria ad acqua calda con imbocchi circolari

.
VBC 315-3 - Systemair
Numero articolo: 9844
VBC 315-3

Batteria ad acqua calda con imbocchi circolari

.
VBF 315 - Systemair
Numero articolo: 1734
VBF 315

Batteria ad acqua calda in cassonetto portafiltro

.
VK-30 - Systemair
Numero articolo: 5641
VK-30

Serranda di sovrapressione

.
Room hygrostat HR-S - Systemair
Numero articolo: 286251
Room hygrostat HR-S

Umidostato per installazione a parete

.