MUB/T 042 400EC

Centrifugal box fan, 120°C continuous, insulated

N° article: 235389

• EC-motors, high level of efficiency
• 100% speed controllable
• Up to 120°C medium temperature, continuous operation
• Multi-functional use, e.g. for kitchen exhaust air
• Pre-assembled isolator is standard
• Low sound level
• Easy to maintain and reliable
• Motor outside the air stream
• Integrated motor protection
• Potentiometer included for ease of commissioning

 

EC technology is intelligent technology; using integral electronic control which eliminates the slip losses in the motor and ensures that the motor always runs at optimal load and guarantees that the proportion of energy utilized effectively is many times higher and the energy usage considerably lower compared with AC motors. EC fans are notable for their economical use of energy and excellent ease of control. They can be varied in speed to match the airflow demand, and operate at high efficiency levels. For the same air volume, they consume distinctly less energy than AC fan drives. Another special feature of EC fans is their energy-saving potential not only at full load, but especially at part-load. When operating at part load, the energy used is much lower than with an asynchronous motor of equivalent output. Reduced energy usage guarantees a drop in operating costs. The power electronics are integrated in the motor housing.

All MUB/T-EC models have one potential-free terminal for error message. All motors are suitable to be used for 50/60Hz. The input voltage for single phase units can vary between 200 and 277V, for three phase units between 380 and 480V. Speed control by a 0-10V signal. The fans are delivered with a pre-wired potentiometer ( 0-10 V) that allowes you to easily find the required working point. All MUB/T-EC fans have impellers with backward curved blades, manufactured from aluminium. The MUB/T-EC fans are suitable for medium temperatures up to 120°C continuously. The casing consists of an aluminium frame with fibreglass reinforced plastic corners and double skin, galvanised steel panels with a 30 mm mineral wool insulation. Panels are removable, allowing flexible ventilation solutions - the air direction (90°) can easily be changed. With quick lock access door. The MUB/T-EC bottom panel is shaped as a condensate tray and incorporates a pre-mounted 1" drain plug. An isolator switch is mounted on the casing.

Several filter modules like f.e. activated carbon- or aluminum filters are available, calculated individually on the working point.

 

Paramètres techniques

Données nominales
Tension (nominale) 230 V
Fréquence 50; 60 Hz
Phases 1~
Puissance installée 550 W
Intensité 2,45 A
Vitesse de rotation 1 512 tr/min
Débit d'air max 4 349 m³/h
Température air en mouvement max 120 °C
Temp. max. avec variateur 120 °C
Protection/Classification
Indice de protection, moteur IP55
Classe d'isolation B
Données selon ErP
Conformité ErP Pas d'ErP pertinent
Dimensions et poids
Poids 55,5 kg
Autres
Type de moteur EC

The Level of Casing-Breakout-Noise depends on the quality of shielding the acoustic inlet and outlet noises.

The shown Level of Casing-Breakout-Noise will be reached only in case of 100 % shielding the acoustic inlet and outlet noise and a correspondingly low environment noise.

MUB/T 042 □A □B □C □D E

400/450/500

690

690

590

548

21

Images Dimensions - MUB/T 042 400EC - Systemair
EC Control - CO2 + Température - Systemair
N° article: 24808
EC Control - CO2 + Température

Controleur d'ambiance- CO2 0-2000ppm+Température 5-30°C-230V

.
EC Control - Humidité - Systemair
N° article: 24807
EC Control - Humidité

Controleur d'ambiance - Humidité 0-100% - 230V

.
EC Control - Température - Systemair
N° article: 24805
EC Control - Température

Controleur d'ambiance - Température 5-30°C - 230V

.
EC Control - Universel 0-10V - Systemair
N° article: 24806
EC Control - Universel 0-10V

Controleur d'ambiance - Universel 0-10V - 230V

.
EC-Vent Régulateur mural - Systemair
N° article: 3115
EC-Vent Régulateur mural .
EC-Vent Tableau de commande - Systemair
N° article: 3018
EC-Vent Tableau de commande .
FGV 042 Manchette - Systemair
N° article: 4605
FGV 042 Manchette

Manchette souple carrée pour MUB 042

.
M-SG 042/588x588 - Systemair
N° article: 301345
M-SG 042/588x588

For air handling units

.
MTP 10 Potentiomètre - Systemair
N° article: 32731
MTP 10 Potentiomètre

Potentiomètre pour moteur EC 0-100% signal: 0-10V

.
MTP 20 Potentiomètre - Systemair
N° article: 310220
MTP 20 Potentiomètre

Potentiomètre pour moteur EC consigne 3 vitesses

.
MTV-1/010 Potentiomètre - Systemair
N° article: 30650
MTV-1/010 Potentiomètre

Potentiomètre pour moteur EC 0-100% signal: 0-10V alim: 230V

.
S-5EC/FRQ - Systemair
N° article: 76738
S-5EC/FRQ

10VDC, IP54, 5 steps

.
SD-MUB Amortisseurs - Systemair
N° article: 37324
SD-MUB Amortisseurs

Amortisseurs de vibrations pour MUB x4

.
UGS 042/400 adapter flex 120°C - Systemair
N° article: 38368
UGS 042/400 adapter flex 120°C

For air handling units

.
UGS 042/500 Refoulement - Systemair
N° article: 4357
UGS 042/500 Refoulement

Raccordement souple gaine circ. refoulement MUB 042 - Ø500mm

.
WSD 042 Capot - Systemair
N° article: 31481
WSD 042 Capot

Capot de protection Alu pour MUB

.
WSG 042 MUB/T complet - Systemair
N° article: 36071
WSG 042 MUB/T complet

Grille d'entrée d'air 042 MUB/T (avec fixations)

.
CO2RT-RD Sonde CO2 Mur - Systemair
N° article: 6993
CO2RT-RD Sonde CO2 Mur

Avec sortie contact inverseur Plage 0-2000ppm - alim: 24V

.
IR24-P Détecteur de présence - Systemair
N° article: 6995
IR24-P Détecteur de présence

Détecteur de présence mural 24V - sortie: contact sec

.
RT 0-30 Thermostat d'ambiance - Systemair
N° article: 5151
RT 0-30 Thermostat d'ambiance

Electronic

.
CCM 400 (42) Aspiration - Systemair
N° article: 311780
CCM 400 (42) Aspiration

Raccordement gaine circulaire aspiration MUB 042 - Ø400mm

.
CCM 400 (42) Refoulement - Systemair
N° article: 311682
CCM 400 (42) Refoulement

Raccordement gaine circulaire refoulement MUB 042 - Ø400mm

.
CCM 500 (42) Aspiration - Systemair
N° article: 311781
CCM 500 (42) Aspiration

Raccordement gaine circulaire aspiration MUB 042 - Ø500mm

.
CCM 500 (42) Refoulement - Systemair
N° article: 311683
CCM 500 (42) Refoulement

Raccordement gaine circulaire refoulement MUB 042 - Ø500mm

.
CCMI outlet 042 d400 KIT 30mm - Systemair
N° article: 239093
CCMI outlet 042 d400 KIT 30mm

insulated flanged plate, for air handling units

.
CCMI outlet 042 d500 KIT 30mm - Systemair
N° article: 239094
CCMI outlet 042 d500 KIT 30mm

insulated flanged plate, for air handling units

.
GRU 042 embase h= 100mm - Systemair
N° article: 276661
GRU 042 embase h= 100mm

pour MUB/CTA taille 042 / hauteur 100mm

.
KKF 30 042-caisson filtre plan - Systemair
N° article: 93311
KKF 30 042-caisson filtre plan

Sans filtre, caisson de 30 mm

.
KKF-ALU 042-caisson filtre - Systemair
N° article: 376815
KKF-ALU 042-caisson filtre

avec filtre alu et bac à graisse

.
KKF-CAR 042-caisson filtre - Systemair
N° article: 277346
KKF-CAR 042-caisson filtre

avec 16 cartouches de filtre à charbon

.
KKF-CAR 062-caisson filtre - Systemair
N° article: 277347
KKF-CAR 062-caisson filtre

avec 25 cartouches de filtre à charbon

.
KKF-KITCHEN 042-caisson filtre - Systemair
N° article: 277363
KKF-KITCHEN 042-caisson filtre

avec filtres alu, plan F7 et carbon actif

.
KKF-KITCHEN 062-caisson filtre - Systemair
N° article: 277364
KKF-KITCHEN 062-caisson filtre

avec filtres alu, plan F7 et carbon actif

.
KKS 042 caisson silencieux - Systemair
N° article: 276851
KKS 042 caisson silencieux

avec 2 baffles intégrés

.
Room hygrostat HR-S - Systemair
N° article: 286251
Room hygrostat HR-S

1 step, 35-95%, IP 30

.