FRQS-E-6A

208-277V, 1~, 6A, IP54, 0-10V

N° article: 37419

Speed controller with 0-10V input for 1~ fans equipped with all pole sine filter

Maximum factory-set output frequency: 50Hz

 

The FRQS-E frequency inverters have integrated all pole sine filters as standard. Therfore there is no need for shielded cables for the installation. This makes the unit also perfectly suited to retrofit into existing systems. The sine filters enable existing non-shielded cables to be retained. This units also reliably control motors which, due to their design, are not usually considered suitable for frequency inverter operation i.e. external rotor motors.

Save and trouble free motor operation with integrated, all pole effective sine filter

Analog input for external speed setup value(0-10 V, 0-20 mA, PWM)

10V DC output for external potentiometer

Potential-free operation notification

Enable contact section for a stand-by switch or electronic reset

Motor protection by connecting thermostats "TB" or thermistors "TP"

Interference emission EN 61000-6-3

Interference immunity EN 61000-6-2

Complete range in IP54

Trouble free parallel operation of motors

No danger to the motors through voltage peaks, bearing current, etc.

No limit of motor cable length

Retrofit in installations with existent wiring(unshielded cables)

Operation without electromagnetic motor noise

Wide voltage range 1~ 208V-277V, 50/60Hz

When operating with Explosion proof fans the FRQ has to be placed outside the EX zone!

Paramètres techniques

Données nominales
Tension 208 à 277 V
Fréquence 50; 60 Hz
Phases 1~
Intensité maximum 6 A
Protection/Classification
Indice de protection IP54
Régulations et sondes
Fusible recommandé 10 A
Humidité relative autorisé sans condensation 0 à 85 %RH
Plage de température, ambiante et conduit
Température ambiante max 55 °C
Dimensions et poids
Poids 5,7 kg
Images Dimensions - FRQS-E-6A - Systemair

 

□A □B C D E øF H G

FRQS-E-6A

250

235

34

210

302

6,5

3,5

195,5

EC Control - CO2 + Température - Systemair
N° article: 24808
EC Control - CO2 + Température

Controleur d'ambiance- CO2 0-2000ppm+Température 5-30°C-230V

.
EC Control - Humidité - Systemair
N° article: 24807
EC Control - Humidité

Controleur d'ambiance - Humidité 0-100% - 230V

.
EC Control - Température - Systemair
N° article: 24805
EC Control - Température

Controleur d'ambiance - Température 5-30°C - 230V

.
EC Control - Universel 0-10V - Systemair
N° article: 24806
EC Control - Universel 0-10V

Controleur d'ambiance - Universel 0-10V - 230V

.
EC Selector - Systemair
N° article: 9908
EC Selector

Sélecteur 3 vitesses pour motorisation EC

.
EC-Vent Régulateur mural - Systemair
N° article: 3115
EC-Vent Régulateur mural .
MTP 10 Potentiomètre - Systemair
N° article: 32731
MTP 10 Potentiomètre

Potentiomètre pour moteur EC 0-100% signal: 0-10V

.
MTP 20 Potentiomètre - Systemair
N° article: 310220
MTP 20 Potentiomètre

Potentiomètre pour moteur EC consigne 3 vitesses

.
MTV-1/010 Potentiomètre - Systemair
N° article: 30650
MTV-1/010 Potentiomètre

Potentiomètre pour moteur EC 0-100% signal: 0-10V alim: 230V

.
S-5EC/FRQ - Systemair
N° article: 76738
S-5EC/FRQ

10VDC, IP54, 5 steps

.