Topvex TX/C06 HWH-R-CAV

Item Number: 94485

• Topvex is delivered with the Access control system

• Space saving top connection

• High efficient counter-flow heat exchanger

- > 80% dry efficiency (EN 308) at nominal airflow

- No mixing of extract and supply air

- Automatic summer operating

- Cool recovering

• Section defrosting

-

The Topvex counter flow unit TX/C (-S

*

) are pre-configured units with Section defrosting

• Low energy use

- Energy efficient plug fans with EC motors

• Large inspection doors for easy maintenance

-

All main components are easy removable

- Separate electrical cabinet facilitates commissioning and service

• Manufactured in Aluzinc plated sheet metal (AZ185)

- Corrosive class C4 (Industrial and coastal areas with moderate salinity)

- AZ185 sheet metal has more than 50 years of technical lifetime

• Factory tested

Topvex TX/C is designed for meeting the coming energy demands with high heat recovery efficiency and low energy use. To guarantee the high heat recovery efficiency the exchanger is designed for low air speed and by that also a low pressure drop. The supply and extract air filter are designed to have a low pressure drop, without compromising with the filtration efficiency. A low internal pressure drop is essential to keep the energy use down Topvex TX/C features Plug fans with EC technology to ensure high efficiency. The EC-motors has when speed-controlled, 15-20% lower energy consumption compared to a standard frequency controlled asynchrony motor.

100% By-pass of heat exchanger secures lowest possible internal pressure drop during the warm season.

A damper isolates the exchanger during the warm period ensures that there is no undesirable heat recovering.

Constant air volume control is standard and Variable air volume control is available as an accessory.

The Topvex counter flow unit TX/C with item name ending -S are pre-configured units with Section defrosting.

The Section defrosting consist of a pre-wired sectioned damper that divides the heat exchanger in three areas plus the by-pass section. All sections are controlled by individual motors for each section and are connected to a separate, pre-programmed control unit.

Section defrosting will prevent severe ice built up in the heat exchanger and allow defrosting of the heat exchanger, while still providing heat recovery through the defrosting sequence.

When activated by pressure detecting, the damper sections will be cyclic operated. Each section will operate in sequence and compensate low temperature in the exhaust air, by modulating the by-pass and section damper.

Topvex is delivered with the new Access control system. The system includes NaviPad control panel, featuring an easy-to-use intuitive HTML5 user interface.

The protection class of the NaviPad control panel is IP54 and 0-50 C° permitted temperature. The enclosure is not UV resistant and the NaviPad is not for outdoor mounting. Communication between the panel and the controller in the cabinet is possible with up to 100 meters of cable.

The NaviPad is connected via 3 meters flat cable. It is mounted on the Topvex unit or on the wall, easy to detach for handheld use.

Relevant operating data and settings are available in real time and can be changed with a few clicks.

Access control has built-in energy saving features like free cooling, cooling recovery, season related temperatures and airflow control.

Possibility to edit names for the unit, the alarms and control components gives the user options to adapt to different installations needs.

With the system overview dashboard it is possible to monitor several air handling units within a local network.

Standard communication possibilities are: Modbus RTU via RS-485 & TCP/IP & BACnet via IP.

Ordering code.

- Model: TX/C03, TX/C04 and TX/C06.

- Heating coil:

EL

(Electric).

HWL

(Hot water coil-low power).

HWH

(Hot water coil-high power).

None

(No heater).

- Right or Left model: R

(Right),

L

(Left). The side where the supply air is located when viewed from the access side.

- Airflow control: CAV

(Constant air volume).

-

Airflow control (accessory):

VAV

(Variable air volume = constant duct pressure control).

-Section defrosting:

-S

(Section defrosting).

*

Section defrosting is available for all Topvex TX/C. Units with item name ending -S are Section defrosting configured.

I.e. Topvex TX/C03 EL-L-CAV-S.

Ecodesign

Product
Trade name Systemair
Product name Topvex TX/C06
Ecodesign
ErP compliance 2018
Unit category NRVU
Unit type BVU
Drive Integrated VSD
Heat recovery type Recuperative
Temperature ratio 80.6 %
qv nom 0.6 m³/s
P nom 1.058 kW
SFPint 1,042 W/(m³/s)
Face velocity 1.4 m/s
Ps nom 200 Pa
Ps int. Supply 238 Pa
Ps int. Extract 352 Pa
Supply Fan efficiency 49.8 %
Extract fan efficiency 62.4 %
External Leakage 2 %
Internal Leakage 1 %
Filter energy performance 1,587 kWh
Sound power level LWA 56 dB(A)

Technical parameters

Unit
Frequency 50 Hz
Voltage (nominal) 400 V
Phase(s) 3~
Recommended fuse 3x10 A
Enclosure class IP23
Speed regulation Stepless
Air flow 0.17 to 0.85 m³/s
Supply fan
Voltage 400 V
Phase(s) 3~
Input power (P1), supply fan 895 W
Supply air filter
Filter class, supply air ePM1 60%
Extract air filter
Filter class, extract air ePM10 60%
Heat exchanger
Exchanger type Counter flow
Return fan / Extract fan
Voltage 400 V
Phase(s) 3~
Input power, extract fan 895 W
Others
Fan control CAV, air flow control; Stepless voltage control
Installation placement Vertical
Supply side Right
Dimensions and weights
Weight 405 kg
ErP
ErP ready ErP 2018

Supply

Extract

1 Outdoor air

2

Supply air

3

Extract air

4

Exhaust air

A B C D E F G H I J K L M

Topvex TX/C06

2150

1630

880

1998

725

116

196

324

140

600

197

300

1065

CO2RT-R-D Transmitter - Systemair
Item Number: 6993
CO2RT-R-D Transmitter .
Presence detector/IR24-PC - Systemair
Item Number: 7288
Presence detector/IR24-PC .
Systemair-1 CO2 duct sensor - Systemair
Item Number: 14906
Systemair-1 CO2 duct sensor .
Systemair-1M CO2 duct sensor - Systemair
Item Number: 14908
Systemair-1M CO2 duct sensor .
Systemair-2 CO2 duct sensor - Systemair
Item Number: 14907
Systemair-2 CO2 duct sensor .
Systemair-E CO2 sensor - Systemair
Item Number: 14904
Systemair-E CO2 sensor .
Systemair-E-D CO2 sensor - Systemair
Item Number: 14905
Systemair-E-D CO2 sensor .
TG-AH3/PT1000 Contact Sensor - Systemair
Item Number: 7899
TG-AH3/PT1000 Contact Sensor .
TG-R5/PT1000 Room sensor 0-50° - Systemair
Item Number: 5404
TG-R5/PT1000 Room sensor 0-50° .
TG-UH3/PT1000 Wall sensor - Systemair
Item Number: 35203
TG-UH3/PT1000 Wall sensor .
VAV Air Volume Control - Systemair
Item Number: 145946
VAV Air Volume Control .
DS 60-30 Flexible connection - Systemair
Item Number: 1547
DS 60-30 Flexible connection .
DXRE 60-35-3-2,5 Duct cooler - Systemair
Item Number: 7956
DXRE 60-35-3-2,5 Duct cooler .
LDR 60-30 Silencer - Systemair
Item Number: 5072
LDR 60-30 Silencer .
PGK 60-35-3-2,0 Duct cooler - Systemair
Item Number: 6612
PGK 60-35-3-2,0 Duct cooler .
VBR 60-30-2 Water heating batt - Systemair
Item Number: 5466
VBR 60-30-2 Water heating batt .
BFT TX/C06 Filter Coarse 50% - Systemair
Item Number: 209932
BFT TX/C06 Filter Coarse 50% .
BFT TX/C06 Filter ePM1 60% - Systemair
Item Number: 209930
BFT TX/C06 Filter ePM1 60% .
BFT TX/C06 Filter ePM10 60% - Systemair
Item Number: 209931
BFT TX/C06 Filter ePM10 60% .
CTTG 400 Roof curb - Systemair
Item Number: 27253
CTTG 400 Roof curb .
CTVX 400 Combi-roof hood Aluz. - Systemair
Item Number: 27246
CTVX 400 Combi-roof hood Aluz. .
F-T120 Timer frame - Systemair
Item Number: 5137
F-T120 Timer frame .
HMH Tube Humidistat IP 54 - Systemair
Item Number: 13209
HMH Tube Humidistat IP 54 .
HU Hygrostat - Systemair
Item Number: 30213
HU Hygrostat .
LDR-B 60-30 Silencer, baffle - Systemair
Item Number: 9240
LDR-B 60-30 Silencer, baffle .
NaviPad extension cable 10m - Systemair
Item Number: 316350
NaviPad extension cable 10m .
Preheat.kit Topvex RB60-30 EL - Systemair
Item Number: 131043
Preheat.kit Topvex RB60-30 EL .
RVAZ4 24A Actuator 0-10V - Systemair
Item Number: 9862
RVAZ4 24A Actuator 0-10V .
TG-KH/PT1000 Duct sensor - Systemair
Item Number: 202705
TG-KH/PT1000 Duct sensor .
TUNE-AHU-SE003-600x300-TF24 - Systemair
Item Number: 79896
TUNE-AHU-SE003-600x300-TF24 .
UG3-A4O Smoke detector - Systemair
Item Number: 15043
UG3-A4O Smoke detector .
Water-lock - Systemair
Item Number: 206263
Water-lock .
ZTR 15-1,0 valve 3-way - Systemair
Item Number: 9672
ZTR 15-1,0 valve 3-way .
ZTV 15-0,6 2-way valve - Systemair
Item Number: 6571
ZTV 15-0,6 2-way valve .