Številka artikla: 5969
Certified according to ATEX
Speed-controllable
Integral thermal contact
Explosion proof
The AW - EX fans have speed controllable external rotor motors. The fans have a square plate for wall mounting and are painted in standard black. The casing and impeller is manufactured from sheet steel. To protect the motor from overheating, integral thermistors are fitted with external leads which must be connected to the U-EK230E motor protection relay.
The AW-Ex fan motor is approved according to ATEX. Useful for Zone 1 and 2, groups IIA, IIB and temperature class T1, T2, or T3 (AW 355 and AW 420 also T4). Ignition protection "e".
Accessories for Ex-fans only on request.
Nominal data | ||
---|---|---|
Napetost (nominalna) | 400 | V |
Frekvenca | 50 | Hz |
Faza | 3~ | |
Priključna moč | 286 | W |
Priključni tok | 0,493 | A |
Vrtljaji vetrnice | 1.341 | rpm |
Zračni pretok | maks ; 2,592; | m³/h |
Temp. transportiranega zraka | maks 40 | °C |
Maks. temp. transportiranega zraka (s hitrostno regulacijo) | 40 | °C |
Podatki o zvoku | ||
---|---|---|
Zvočni tlak na 3m (20m2 prostor) | 62 | dB(A) |
Zaščita / klasifikacija | ||
---|---|---|
Zaščitni razred, motor | IP44 | |
Izolacijski razred | F | |
Oznaka za eksplozijsko odpornost | II 2G c Ex e IIB T4 | |
Certifikat | ZELM 05ATEX0279X |
Podatki v skladu z ErP | ||
---|---|---|
Pripravljeno za ErP | Not ErP relevant |
Krmilnik in tipala | ||
---|---|---|
Temperatura v prostoru in kanalu | -20 do 40 | °C |
Dimenzije in teža | ||
---|---|---|
Teža | 9 | kg |
Drugi | ||
---|---|---|
Tip motorja | AC |
U1 |
brown |
V1 |
blue |
W1 |
black |
U2 |
red |
V2 |
grey |
W2 |
orange |
K |
white |
PE |
green/yellow |
Test-voltage on temperature sensor max. 2,5V.
A | B | C | D | E | F | G | H | I | J | |
AW 355 EX |
138 |
48 |
70 |
16 |
350.5 |
356 |
125 |
4x12 |
385 |
423 |
The box is made out of electroplated steel plate, powder- coated. Including protection guard. The installation is possible in each fitting position. The fan has an axial impeller with airfoils made out of electroplated, powder- coated steel plate. The actuation is carried out by an explosion- proofed, speed- controllable external rotor motor with completed barretter. A D/Y- capability of connection allows an double- rotation operation of the motor. For annealing the motor is situated inside the air flow. Impeller according to VDI 2060, quality class Q 6,3 and dynamically weigh heavy in two levels. Tested according to ATEX- Guideline 94-9-EG,conform to ATEX Directive 2014/34/EU. For the extraction of potentially explosive atmosphere of zone 1, category 2G and zone 2, category 3G. The fans are in zone 1, 2 and for the temperature levels T1, T2 and T3 applicable. The explosion group is "e" elevated safety Eexe II, T3. Appurtenances for the Ex- fan is available on enquiry.