Cod produs: 95375
Octagonal casing is manufactured from seawater resistant aluminium. The base frame consists of hot-dip galvanised steel. Impeller with backward-curved blades is manufactured from galvanised steel. For C4 (and up) corrosion category additional surface protection of exposed parts is recommended.
Motor cooling with fresh air via air duct. The motor protection is provided by customers. Service switch serial on cooling duct. For speed control of single speed motors use combination of frequency converter and appropriate filter to motor side (sine or du/dt), respectively observe instructions. At frequency controlled units additional EMC protection could be needed (on request).
Date nominale | ||
---|---|---|
Tensiune (nominală) | 400 | V |
Frecvență | 50 | Hz |
Faza (e) | 3~ | |
Conexiune la circuitul motorului | YY | |
Putere de intrare | 23916 | W |
Putere nominală la arbore (P2) | 22 | kW |
Curent de pornire | 315 | A |
Curent de intrare | 39,8 | A |
Viteza elicei | 1484 | rpm |
Flux de aer | max 51001 | m³/h |
Temperatura aerului transportat | max 120 | °C |
Date acustice | ||
---|---|---|
Nivelul presiunii sonore la 10 m (câmp liber) | 78 | dB(A) |
Nivelul presiunii sonore la 4 m (câmp liber) | 86 | dB(A) |
Protecție / Clasificare | ||
---|---|---|
Clasa de incintă, motor | IP55 | |
Clasa de izolare | F |
Date conform ErP | ||
---|---|---|
Gata pentru ErP | Nu este relevant pentru ErP |
Dimensiuni și greutăți | ||
---|---|---|
Dimensiune tubulatură; Circular, intrare | 800 | mm |
Dimensiune tubulatură; Circular, ieșire | 800 | mm |
Greutate | 471 | kg |
Altele | ||
---|---|---|
Tip conexiune tubulatură | Circular | |
Tip motor | AC |
Lock the service switch in position ON to prevent unintended switch OFF! |
Lock is not in scope of fan. |
Upper connection: low speed |
Lower connection: high speed |
Mid-frequency band, Hz | ||||||||||
1000D4-XM |
Hz |
Tot |
63 |
125 |
250 |
500 |
1k |
2k |
4k |
8k |
LwA Inlet |
dB(A) |
104 |
82 |
91 |
97 |
100 |
96 |
94 |
92 |
80 |
LwA Surrounding |
dB(A) |
108 |
86 |
95 |
101 |
104 |
100 |
98 |
96 |
84 |
Measuring point: qv = 7,3 m3/s, ps = 1600 Pa |
Mid-frequency band, Hz | ||||||||||
1000D8-XM |
Hz |
Tot |
63 |
125 |
250 |
500 |
1k |
2k |
4k |
8k |
LwA Inlet |
dB(A) |
84 |
66 |
72 |
75 |
79 |
76 |
76 |
71 |
60 |
LwA Surrounding |
dB(A) |
85 |
67 |
73 |
76 |
80 |
77 |
77 |
72 |
61 |
Measuring point: qv = 3,1 m3/s, ps = 430 Pa |
4-pol
8-pol
DVV 1000 |
Roof fan, vertical blowing. The DVV-XS...XP/120 radial fans are intended for the normal daily ventilation, temperature of air up to 120°C. The base plate with inlet cone is made of hot-dip galvanized steel sheet. The outer octagonal casing from seawater-resistant aluminium. Bird protection grill inside casing. The air stream is carried out through annular space between the casing and the motor housing. The fan has a backward curved radial impeller made of galvanized steel. With hub and secured bolted joint directly assembled on the motor shaft. Dynamically balanced according to ISO 1940 T1 quality class G6,3. Driven by two-speed IE1 motor, separate windings (4-6, 6-8), respectively Dahlander (4-8, 6-12). PTC thermal protection serial built-in electric motor. Cooling of the motor with ambient air through an air duct in underpressure system. The motor protection is provided by customers. Connection the fan to the mains in service switch outside on the casing. For speed control use combination of frequency inverter and appropriate filter to motor side (sine or du/dt), respectively observe instructions. EMC protection (for frequency control, if needed) on request, serial not EMC protected cables, cable glands and service switches are used. Flange connection according to EUROVENT. An additional sound attenuator HSDV (preferable factory mounted) is available as accessorie (the marking of the fan with silencer is DVVI).
Nume fișier document | Tip fișier document | |
---|---|---|
DVV_F_DVV_120_E8302_31_08_15.pdf | Broșură | |
IMO_DVV | Manual | |
DVV_4g_1000_F6_00.dxf | Fișier CAD |