Rectangular, for air handling units
Prekės Numeris: 5073
Silencer
Easily-fitted silencer immediately before or after the KE, KT, RS and RSI rectangular duct fans. Effectively suppresses noise transmitted to the duct. The silencer should be used together with an insulated fan where there is a requirement for noise suppression both in the duct and in the surroundings as a whole. All silencers are supplied with a universal flange suitable for PG flange or Metu profile.
Išmatavimai ir svoriai | ||
---|---|---|
Duct dimension, inlet (height x width) | 350 x 600 | mm |
Duct dimension, outlet (height x width) | 350 x 600 | mm |
Svoris | 21,3 | kg |
Kita | ||
---|---|---|
Ortakio pajungimo tipas | Stačiakampis |
|
|
|
Plotas m2 |
P reikšmė |
LDR 30-15 | 0.045 | 3.5 |
LDR 40-20 |
0.08 |
3.6 |
LDR 50-25 |
0.125 |
3.7 |
LDR 50-30 |
0.15 |
3.3 |
LDR 50-40 |
0.2 |
3.0 |
LDR 60-30 |
0.18 |
3.3 |
LDR 60-35 |
0.21 |
3.0 |
LDR 70-40 |
0.28 |
3.1 |
LDR 80-50 |
0.40 |
3.6 |
LDR 100-50 |
0.50 |
3.6 |
|
|
|
Slėgio kritimo apskaičiavimas slopintuvams
Šis apskaičiavimas galioja tik tuo atveju jei slopintuvas prie ortakio prijungtas abiejuose galuose.
Pavyzdys: Slėgio kritimo apskaičiavimas slopintuvui LDR 60-35 (ventiliatoriaus modelis RSI 60-35 M3-), pasinaudojant dešinėje pusėje parodyta diagrama.
1. Pradėkime nuo frontalinio ploto nustatymo (žr. lentelę).
2. Diagramoje B judame horizontaliai į dešinę iki susikirtimo su projektiniu oro srautu.
3. Kylame aukštyn į diagramą A, kol pasieksime reikiamą slėgio reikšmę (3,0)
4. Diagramoje A judame horizontaliai i kairę iki susikirtimo su vertiklaia ašimi. Nuskaitome slėgio kritimo reikšmę.
Šiame pvz. slėgio kritimas lygus 27Pa.
Triukšmo slopinimas dB (vid.dažnis, Hz) |
|
125 | 250 | 500 | 1k | 2k | 4k | 8k |
LDR 30-15 |
7 |
15 |
18 |
25 |
25 |
19 |
19 |
LDR 40-20 |
5 |
9 |
15 |
23 |
16 |
12 |
10 |
LDR 50-25 |
10 |
15 |
25 |
25 |
20 |
15 |
12 |
LDR 50-30 |
8 |
15 |
20 |
31 |
17 |
14 |
11 |
LDR 60-30 |
8 |
15 |
20 |
31 |
17 |
14 |
11 |
LDR 60-35 |
7 |
13 |
17 |
18 |
13 |
10 |
8 |
LDR 70-40 |
7 |
11 |
14 |
14 |
10 |
8 |
6 |
LDR 80-50 |
6 |
8 |
10 |
11 |
8 |
6 |
3 |
LDR 100-50 |
6 |
8 |
10 |
11 |
8 |
6 |
3 |
B | H | |
LDR 30-15 |
300 |
150 |
LDR 40-20 |
400 |
200 |
LDR 50-25 |
500 |
250 |
LDR 50-30 |
500 |
300 |
LDR 50-40 |
500 |
400 |
LDR 60-30 |
600 |
300 |
LDR 60-35 |
600 |
350 |
LDR 70-30 |
700 |
300 |
LDR 70-40 |
700 |
400 |
LDR 80-40 |
800 |
400 |
LDR 80-50 |
800 |
500 |
LDR 90-30 |
900 |
300 |
LDR 100-50 |
1000 |
500 |
LDR 110-30 |
1100 |
300 |
LDR 120-50 |
1200 |
500 |