Numero articolo: 95433
Roof fans DVV-Ex are designed to exhaust potentially explosive atmospheres (mixtures of air and inflammables such as gases and steam) from explosion hazardous areas. The DVV-Ex fans have impellers with backward-curved blades and IEC motor in explosion protection "flameproof enclosure" - Ex d. The casing is manufactured from seawater-resistant aluminium and the base frame from hot dip galvanised steel, with a copper inlet cone.
Suitable for exhaust from zones 1 or 2, field of application II, for gases of groups A and B and temperature classes T1 to T4. The fans are classified to category 2G. Terminal box in explosion protection "increased safety" - II 2G Ex e IIC T5/T6 is mounted on the casing. Up to request additionally equipped and marked fans are available to achieve extended temperature respectively gas range: II 2G c IIB T3 (-20 < Ta < 55°C), II 2G c IIB+H2 T3 (-20 < Ta < 55°C), II 2Gc IIB T4 (-40 < Ta < 40°C).
To enable protection of motor from overheating DVV-Ex fans have serial built-in thermistors (PTC) with external leads (connection to U-EK230E motor protection relay as accessory possible). On request the fan can be factory fitted with sound attenuator HSDV (accessory) on outlet (marking of the fan DVVI-Ex).
Dati nominali | ||
---|---|---|
Voltaggio (nominale) | 400 | V |
Frequenza | 50 | Hz |
Fasi | 3~ | |
Collegamento elettrico motore | Y | |
Potenza in entrata | 1.850 | W |
Corrente allo spunto | 17,7 | A |
Corrente in entrata | 3,4 | A |
Velocità rotazione girante | 1.419 | rpm |
Portata aria | max ; 10,199; | m³/h |
Temperatura aria trasportata | max 40 | °C |
Dati acustici | ||
---|---|---|
Livello pressione sonora a 10 m (campo libero) | 61 | dB(A) |
Livello pressione sonora a 4 m (campo libero) | 68 | dB(A) |
Protezione/Classificazione | ||
---|---|---|
Classe di protezione, motore | IP55 | |
Classe d'isolamento | F | |
A prova di esplosione | II 2G c IIBT4 | |
Certificato | SIQ 14 ATEX 143X |
Dati in accordo a ERP | ||
---|---|---|
Pronto ErP | Non pertinente ErP |
Temperatura ambiente e canale | ||
---|---|---|
Temperatura ambiente e canale | -20 a 40 | °C |
Resistenza | 8,3 | Ω |
Dimensioni e pesi | ||
---|---|---|
Dimensione condotto; Circolare, immissione | 560 | mm |
Dimensione condotto; Circolare, immissione | 560 | mm |
Peso | 106 | kg |
Altri | ||
---|---|---|
Tipo connessione condotto | Circolare | |
Tipo motore | AC |
Mid-frequency band, Hz |
560D4-XM | Hz | Tot | 63 | 125 | 250 | 500 | 1k | 2k | 4k | 8k |
LwA Inlet |
dB(A) |
86 |
49 |
78 |
78 |
77 |
77 |
79 |
77 |
69 |
LwA Surrounding |
dB(A) |
87 |
59 |
69 |
77 |
81 |
81 |
82 |
78 |
70 |
Measuring point: qv = 2,3 m³/s, Ps = 290 Pa |
|
□A | □B | □C | øF | øG | H | I | K | ød1 | ød2 | nxM |
DVV-EX 560 |
750 |
939 |
943 |
560 |
361 |
990 |
892 |
90 |
620 |
14 |
12xM8 |
Roof radial fan, vertically blowing, for extraction of potentially explosive atmospheres.
Suitable for exhaust from zones 1 or 2, field of application II, for gases of groups A and B and temperature classes T1 to T4.
The fans are classified to category 2G. Marking of explosion protection of serial equipped fan: II 2G c IIB T4. Certificate SIQ 14 ATEX 143X.
The casing is made up of seawater- resistant aluminium, the base frame of hot dip galvanized steel, with copper inlet cone and bird protection. Flange connection on the sucking side according to Eurrovent. The fan has a backwards- curved galvanized steel impeller. Impeller is with hub and secured bolted joint directly assembled on the motor shaft.
The fan has an IEC motor in explosion protection "flameproof enclosure" - Ex d. Suitable for frequency control. The motor has built-in thermistors (PTC) with external leads. Terminal box in explosion protection "increased safety" - Ex e is mounted outside on casing.
Factory mounted sound attenautor HSDV on request (as DVVI-Ex fan).
Nome documento | Tipo documento | |
---|---|---|
DVV_EX_E8304_18_5_2015.pdf | Brochure | |
IMO_DVV4G_EX_DE_EN_23_02_2015_AM_13_02_2018.PDF | Manuale | |
DVV_Ex_560.dxf | File CAD | |
SIQ14ATEX143X_EN.PDF | Certificato |