DVV 1000D4-6-XP/120°C

Numero articolo: 95384

• Motor outside of the air stream
• Vertical exhaust of media up to 120°C permanently
• Suitable for coastal applications
• Wide range of accessories
• IE3 high efficiency motor (single speed) respectively two speed IE1 motor inside
• PTC thermal protection serial built-in motor
• Sucking side connection acc. EUROVENT
• Sound attenuator available as accessorie HSDV (preferable factory mounted, the marking of the fan with silencer is DVVI)

 

Octagonal casing is manufactured from seawater resistant aluminium. The base frame consists of hot-dip galvanised steel. Impeller with backward-curved blades is manufactured from steel and galvanized. For C4 (and up) corrosion category additional surface protection of exposed parts is recommended.

 

Motor cooling with fresh air via air duct. The motor protection is provided by customers. Service switch serial on cooling duct. For speed control of single speed motors use combination of frequency inverter and appropriate filter to motor side (sine or du/dt), respectively observe instructions. At frequency controlled units additional EMC protection could be needed (see also items with EMC protection - marked EMC, other are available on request).

 

Eco design

Prodotto
Nome commerciale Systemair
Nome prodotto DVV 1000D4-6-XP/120°C
Eco design
In accordo a ERP 2016
Categoria unità NRVU
Trasmissione MSD o VSD esterno
tipo unità UVU
Tipo recupero di calore Nessuno
Rapporto temperatura (UVU) Non disponibile
Qv nom 9,444 m³/s
P nom 30,433 kW
Pressione stat. nominale 1.751 Pa
Rendimento ventilatore 54,6 %
Trafilamento esterno 0 %
Livello potenza sonora LWA 109 dB(A)

Parametri tecnici

Dati nominali
Voltaggio (nominale) 400 V
Frequenza 50 Hz
Fasi 3~
Collegamento elettrico motore Y
Potenza in entrata 30.433 W
Potenzaassorbita all'asse (P2) (Nominale) 28 kW
Corrente allo spunto 360 A
Corrente in entrata 53,5 A
Velocità rotazione girante 1.458 rpm
Portata aria max 56.002 m³/h
Temperatura aria trasportata max 120 °C
Dati acustici
Livello pressione sonora a 10 m (campo libero) 80 dB(A)
Livello pressione sonora a 4 m (campo libero) 88 dB(A)
Protezione/Classificazione
Classe di protezione, motore IP55
Classe d'isolamento F
Dati in accordo a ERP
Pronto ErP ErP 2016; Non pertinente ErP
Dimensioni e pesi
Dimensione condotto; Circolare, immissione 800 mm
Dimensione condotto; Circolare, immissione 800 mm
Peso 519 kg
Altri
Tipo connessione condotto Circolare
Tipo motore AC
Mid-frequency band, Hz

1000D6-XP

Hz

Tot

63

125

250

500

1k

2k

4k

8k

LwA Inlet

dB(A)

93

75

81

84

88

85

85

80

69

LwA Surrounding

dB(A)

96

78

84

87

91

88

88

83

72

Measuring point: qv = 7,1 m3/s, ps = 620 Pa

Mid-frequency band, Hz

1000D4-XP

Hz

Tot

63

125

250

500

1k

2k

4k

8k

LwA Inlet

dB(A)

105

82

91

97

101

96

94

92

80

LwA Surrounding

dB(A)

109

86

95

101

105

100

98

96

84

Measuring point: qv = 9,2 m3/s, ps = 1800 Pa

6-pol

4-pol

Images Dimensions - DVV 1000D4-6-XP/120°C - Systemair
DVV 1000

Roof fan, vertical blowing. The DVV-XS...XP/120 radial fans are intended for the normal daily ventilation, temperature of air up to 120°C. The base plate with inlet cone is made of hot-dip galvanized steel sheet. The outer octagonal casing from seawater-resistant aluminium. Bird protection grill inside casing. The air stream is carried out through annular space between the casing and the motor housing. The fan has a backward curved radial impeller made of galvanized steel. With hub and secured bolted joint directly assembled on the motor shaft. Dynamically balanced according to ISO 1940 T1 quality class G6,3. Driven by two-speed IE1 motor, separate windings (4-6, 6-8), respectively Dahlander (4-8, 6-12). PTC thermal protection serial built-in electric motor. Cooling of the motor with ambient air through an air duct in underpressure system. The motor protection is provided by customers. Connection the fan to the mains in service switch outside on the casing. For speed control use combination of frequency inverter and appropriate filter to motor side (sine or du/dt), respectively observe instructions. EMC protection (for frequency control, if needed) on request, serial not EMC protected cables, cable glands and service switches are used. Flange connection according to EUROVENT. An additional sound attenuator HSDV (preferable factory mounted) is available as accessorie (the marking of the fan with silencer is DVVI).

ASFV G800-1000 - Systemair
Numero articolo: 95219
ASFV G800-1000 .
ASG/F 800-1000 - Systemair
Numero articolo: 95215
ASG/F 800-1000 .
ASSG/F 800-1000 - Systemair
Numero articolo: 95214
ASSG/F 800-1000 .
HSDV 1000-XL/XM/XP - Systemair
Numero articolo: 95358
HSDV 1000-XL/XM/XP .
U-EK230E EX - Systemair
Numero articolo: 30199
U-EK230E EX .
VKG/F 800-1000 - Systemair
Numero articolo: 95133
VKG/F 800-1000 .
VKGM 800-1000 - Systemair
Numero articolo: 95508
VKGM 800-1000 .