Torrino isolato a scarico verticale con motore EC
Numero articolo: 79293
Integrated pressure sensor
Temperature sensor for outdoor temperature compensation
Multipurpose LC display and keyboard
100 % speed controllable
Integrated motor protection
Safe and maintenance free operation
Energy-saving
Sizes 315 up to 500 inclusive tilting device
Alarm relay(2A, 250VAC)
Two RS-485 interfaces for networking via MODBUS RTU
The DVCI-POC roof fans are driven by EC- external rotor motors, so called energy saving motors with high efficiency. The input voltage for single phase units can vary between 200 and 277V, for three phase units between 380 and 480V. All motors are suitable for 50Hz and 60Hz and from size 355 up to 710 suspended on effective vibration dampers. Motor protection is integrated in the electronics of the motor, no additional external motor protection device is needed.
The DVCI-POC versions have integrated pressure sensors and temperature sensor for outdoor temperature compensation. The electronics could be programmed for a pressure constant operation or pressure constant operation with outdoor temperature compensation. The factory setting is pressure constant operation with outdoor temperature compensation. All set point adjustments over the keyboard and all values were shown on the LC display. The purpose of the controller is to reach and maintain the target values set. To accomplish this, the measured actual value (sensor value) is compared with the adjusted target value, and the controlled value (modulation) is deduced from this. Controlled output of the controller is 0 - 10 V.
The casing is made from seawater-resistant aluminum,
soundproofed with 50mm mineral wool.
Base frame from galvanised steel. Backward curved impellers manufactured from polypropylen PP for size 315-710.
Prodotto | ||
---|---|---|
Nome commerciale | Systemair | |
Nome prodotto | DVCI 315-POC+FTG |
Eco design | ||
---|---|---|
In accordo a ERP | 2018 | |
Categoria unità | NRVU | |
Trasmissione | VSD integrato | |
tipo unità | UVU | |
Tipo recupero di calore | Nessuno | |
Rapporto temperatura (UVU) | Non disponibile | |
Qv nom | 0,329 | m³/s |
P nom | 0,174 | kW |
Pressione stat. nominale | 263 | Pa |
Rendimento ventilatore | 49 | % |
Trafilamento esterno | 0 | % |
Livello potenza sonora LWA | 62 | dB(A) |
Dati nominali | ||
---|---|---|
Voltaggio (nominale) | 230 | V |
Frequenza | 50; 60 | Hz |
Fasi | 1~ | |
Potenza in entrata | 174 | W |
Corrente in entrata | 1,37 | A |
Velocità rotazione girante | 1.568 | rpm |
Portata aria | max 2.369 | m³/h |
Temperatura aria trasportata | max 60 | °C |
Temperatura max aria trasportata, sotto regolazione | 60 | °C |
Dati acustici | ||
---|---|---|
Livello pressione sonora a 10 m (campo libero) | 31 | dB(A) |
Livello pressione sonora a 4 m (campo libero) | 39 | dB(A) |
Protezione/Classificazione | ||
---|---|---|
Classe di protezione, motore | IP54 | |
Classe d'isolamento | B |
Dati in accordo a ERP | ||
---|---|---|
Pronto ErP | ErP 2016; ErP 2018 |
Dimensioni e pesi | ||
---|---|---|
Peso | 21,6 | kg |
Altri | ||
---|---|---|
Tipo motore | EC |
Banda di frequenza media, Hz |
|
Hz | Tot | 63 | 125 | 250 | 500 | 1k | 2k | 4k | 8k |
LwA Inlet |
dB(A) |
65 |
36 |
51 |
57 |
61 |
58 |
53 |
49 |
47 |
LwA Surrounding |
dB(A) |
62 |
35 |
51 |
54 |
58 |
57 |
50 |
41 |
39 |
Measuring point: qv = 0, 33 m³/s, Ps = 263 Pa |
|
|
|
|
|
|
|
|
|
|
|
DVCI-POC |
□A |
□B |
□C |
D |
□E |
□F |
H |
K |
øI |
L |
315 |
690 |
583 |
369 |
392,5 |
435 |
330 |
6xM6 |
285 |
10(4x) |
463 |
.
Nome documento | Tipo documento | |
---|---|---|
L-BAL-E231-GB_QUICK START-.PDF | Manuale | |
L-BAL-E234-GB_MANUAL-.PDF | Manuale | |
MANUAL_ROOF_FANS_EN_001_.PDF | Manuale | |
EU DECLARATION OF CONFORMITY_ROOF FANS_EN_004.PDF | Dichiarazione |
Flange circolari per collegamento in aspirazione.
Raccordo per collegamento accessori e silenziatore
Giunti flessibili flangiati a sezione circolare.
indication of angle with order ... °, for air handling units