Item number: 251437
Decentralized mechanical extract ventilation, constant flow
Single flow decentralised mechanical ventilation unit for continuous running, Ø100mm, constant volume and low consumption. Ideal for
application in bathroom, toilet and small/medium premises. Suitable to extract stale air directly to the outside or through medium-long length ducting.
Units can be wall/panel, ceiling and window mounted.
Casing made of high quality ABS provides long lasting shock-proof and robust construction. The unit is finished in white RAL 9010 and are UV resistant.
High efficient mixed flow impeller, providing enhanced aerodynamic properties, low noise and increased performances.
EC brushless motor with integral thermal protection, mounted on sealed for life high quality ball bearings to assure a longer fan life and
ideal for cold climates.
Ecodesign | ||
---|---|---|
ErP sukladnost | 2018 | |
Jedinica kategorije | RVU | |
Pogon | Vanjski MSD ili VSD | |
Vrsta jedinice | UVU | |
Vrsta povrata topline | Nijedan | |
Omjer temperature (UVU) | Nije primjenjivo | |
qv nom | 0,0208 | m³/s |
P nom | 0,005 | kW |
P nom | 25 | Pa |
Učinkovitost ventilatora | 11,2 | % |
Osnovna jedinica | ||
---|---|---|
ErP sukladnost | 2018 | |
SEC Prosjek | -14,36 | kWh/(m².a) |
SEC Hladno | -30,76 | kWh/(m².a) |
SEC Vruće | -4,97 | kWh/(m².a) |
DZS Klasa | E | |
Jedinica kategorije | RVU | |
Vrsta jedinice | UVU | |
Pogon | Vanjski MSD ili VSD | |
Vrsta povrata topline | Nijedan | |
Omjer temperature (UVU) | Nije primjenjivo | |
qv max | 75 | m³/h |
Pmax | 5 | W |
qv ref | 0,0144 | m³/s |
Ps ref | 50 | Pa |
SPI | 50 | W/(m³/h) |
CTRL | 1 | |
MISC | 1,1 | |
x-vrijednost | 1,5 | |
Vanjsko propuštanje | Nije primjenjivo | |
AEC prosjek | 112 | kWh |
AHS Hladno | 112 | kWh |
AEC toplo | 112 | kWh |
AHS prosjek | 17 | kWh/a |
AHS Hladno | 34 | kWh/a |
AHS toplo | 8 | kWh/a |
Jedinice s autonomnim zahtjevom regulacije | ||
---|---|---|
ErP sukladnost | 2018 | |
SEC Prosjek | 26,84 | kWh/(m².a) |
SEC Hladno | 53,9 | kWh/(m².a) |
SEC Vruće | 11,33 | kWh/(m².a) |
DZS Klasa | B | |
Jedinica kategorije | RVU | |
Vrsta jedinice | UVU | |
Pogon | Vanjski MSD ili VSD | |
Vrsta povrata topline | Nijedan | |
Omjer temperature (UVU) | Nije primjenjivo | |
qv max | 75 | m³/h |
Pmax | 5 | W |
qv ref | 0,0144 | m³/s |
Ps ref | 50 | Pa |
SPI | 0,089 | W/(m³/h) |
CTRL | 0,65 | |
MISC | 1,1 | |
x-vrijednost | 1,5 | |
Vanjsko propuštanje | Nije primjenjivo | |
AEC prosjek | 58 | kWh |
AEC hladno | 58 | kWh |
AEC toplo | 58 | kWh |
AHS prosjek | 28 | kWh/a |
AHS Hladno | 55 | kWh/a |
AHS toplo | 13 | kWh/a |
Nominalni podaci | ||
---|---|---|
Napon (nazivni) | 230 | V |
Frekvencija | 50 | Hz |
Faze | 1~ | |
Ulazna snaga | 5 | W |
Ulazna struja | 0,072 | A |
Brzina rotora | 2.680 | rpm |
Protok zraka | 0 do 106 | m³/h |
Temperatura transportiranog zraka | maks 50 | °C |
Podaci o zvuku | ||
---|---|---|
Razina zvučnog tlaka na 3 m (slobodno polje) | 32 | dB(A) |
Zaštita/Klasifikacija | ||
---|---|---|
Klasa zaštite, motor | IPX4 | |
Klasa izolacije | B |
Podaci prema ErP | ||
---|---|---|
Energetska klasa, Osnovna jedinica | B | |
Energetska klasa, Lokalna zahtjev | E | |
ErP spreman | ErP 2018 |
Dimenzije i težine | ||
---|---|---|
Dimenzija kanala; Kružni ulaz | 100 | mm |
Masa | 0,6 | kg |
Ostali | ||
---|---|---|
Vrsta motora | AC |
BF 100MX | □A | B | C | øD | E | [mm] |
164 |
46 |
82 |
99 |
101 |
Document filename | Document filetype | |
---|---|---|
MANUAL_INSTALLATION_BF_100MX_MULTILINGUAL.PDF | Manual | |
BF_100MX_SYSTEMAIR.PDF | Technical Data sheets |