FRQS-4A V2 frekv.regulator

Item number: 36231

Speed controller with 0-10V input for 3~ fans equipped with all pole sine filter

Maximum factory-set output frequency: 50Hz

 

The FRQS/FRQ5S frequency inverters have integrated all pole sine filters as standard. Therfore there is no need for shielded cables for the installation This makes the unit also perfectly suited to retrofit into existing systems. The sine filters enable existing non-shielded cables to be retained. This units also reliably control motors which, due to their design, are not usually considered suitable for frequency inverter operation i.e. external rotor motors.

Save and trouble free motor operation with integrated, all pole effective sine filter

Analog input for external speed setup value(0-10 V, 0-20 mA, PWM)

10V DC output for external potentiometer

Potential-free operation notification

Enable contact section for a stand-by switch or electronic reset 

Motor protection by connecting thermostats "TB" or thermistors "TP"

Interference emission EN 61000-6-3

Interference immunity EN 61000-6-2

Complete range in IP54

Trouble free parallel operation of motors

No danger to the motors through voltage peaks, bearing current, etc.

No limit of motor cable length

Retrofit in installations with existent wiring(unshielded cables)

Operation without electromagnetic motor noise

Wide voltage range 3~ 208V-480V, 50/60Hz

When operating with Explosion proof fans the FRQ has to be placed outside the EX zone!

Tehnički parametri

Nominalni podaci
Nazivni napon 208 do 480 V
Frekvencija 50; 60 Hz
Faze 3~
trenutni maksimum 4 A
Zaštita/Klasifikacija
Klasa zaštite IP54
Regulator i senzori
Preporučeni osigurač 10 A
Temperatura okoline i kanala
Dopuštena temperatura okoline maks 40 °C
Dimenzije i težine
Masa 5,32 kg
Images Dimensions - FRQS-4A V2 frekv.regulator - Systemair
EC-Basic-CO2 i temp. - Systemair
Item number: 24808
EC-Basic-CO2 i temp. .
EC-Basic-H vlaga - Systemair
Item number: 24807
EC-Basic-H vlaga .
EC-Basic-T temperatura - Systemair
Item number: 24805
EC-Basic-T temperatura .
EC-Basic-U universal 0-10V - Systemair
Item number: 24806
EC-Basic-U universal 0-10V .
EC-Selector - Systemair
Item number: 9908
EC-Selector .
EC-VENT KONTROLNA KARTICA - Systemair
Item number: 3115
EC-VENT KONTROLNA KARTICA .
MTP 10, 10K NASTAVLJANIK ZA EC - Systemair
Item number: 32731
MTP 10, 10K NASTAVLJANIK ZA EC .
MTP 20, on/off, 3-stop - Systemair
Item number: 310220
MTP 20, on/off, 3-stop .
MTV-1/010 0-10V POZICIONER - Systemair
Item number: 30650
MTV-1/010 0-10V POZICIONER .
Step switch S-5EC, 0-10V - Systemair
Item number: 76738
Step switch S-5EC, 0-10V .