RVK-EX 315D4

Centrifugal circular duct fan,ex.proof, II 2G Ex h IIB+H2 T3

N° article: 237943

According to ATEX Directive 2014/34/EU

Speed controllable

Can be installed in any position

Motorprotection over cold conductor

The RVK fans are designed for installation in ducts. The fans have backward curved blades and external rotor motors.

The RVK-EX 315D4 can be controlled by reducing voltage via 5-step controller in combination with the Systemair Standard tripping unit U-EK230E EX.

The RVK-EX 315D4 fan complies with the ATEX regulation. The fans could be used for zone 1 and zone 2; Field of application for gases of groups IIA, IIB and also hydrogen, temperature class T1, T2 and T3. The casing is made from conducting plastic. The fans are certified under the no TPS 20 ATEX 085751 0009 X.

Explosion proof version comply with EN 60079-0, EN 60079-7, EN 14986, DIN EN ISO 80079-36 and DIN EN ISO 80079-37.

NB. Motor protection device U-EK230E EX must always be connected.

Paramètres techniques

Données nominales
Tension (nominale) 400 V
Fréquence 50 Hz
Phases 3~
Puissance installée 84 W
Intensité 0,2 A
Vitesse de rotation 1 385 tr/min
Débit d'air max 1 120 m³/h
Température air en mouvement max 40 °C
Temp. max. avec variateur 40 °C
Données acoustiques
Niveau sonore à 3 m (20m² Sabine) 41 dB(A)
Protection/Classification
Indice de protection, moteur IP44
Classe d'isolation B
Antidéflagrant II 2G Ex h IIB+H2 T3 Gb
Certificat TPS 20 ATEX 085751 0009 X
Plage de température, ambiante et conduit
Plage de température, ambiante et conduit -20 à 40 °C
Dimensions et poids
Conduit Circul d'aspiration 315 mm
Conduit Circul de refoulement 315 mm
Poids 7 kg
Autres
Type de connexion Circulaire
Designation couleur carrosserie Noir
Type de moteur AC
Images Dimensions - RVK-EX 315D4 - Systemair

 

 

 

 

 

 

 

 

øA

øB

C

D

E

F

G

RVK-EX 315

314

405

264

30,5

225

200

60

The box is made out of conductive plastics.

The fan has a backward- curved radial impeller made out of powder-coated steel plate.

The actuation is carried out by an explosion- proofed, speed-controllable external rotor motor with PTC.

For annealing the motor is situated inside the air flow.

Motor completely with impeller statically and dynamically weigh heavy according to DIN ISO 1940.

Tested according to ATEX- Guideline 2014/34/EU.

For the extraction of potentially explosive atmosphere of zone 1, category 2G and zone 2, category 3G.

Field of application for gases of groups IIA, IIB and hydrogen.

Clasification: II 2G Ex h IIB+H2 T3 Gb

Appurtenances for the Ex- fan is available on enquiry.

ATEX-approval number TPS 20 ATEX 085751 0009 X.

R-DK4 KT Auto-transformateur - Systemair
N° article: 6051
R-DK4 KT Auto-transformateur

Auto-transformateur 5 vitesses triphasé (400V+N) 4A

.
RTRD 2 Auto-transformateur - Systemair
N° article: 5941
RTRD 2 Auto-transformateur

Auto-transformateur triphasé 5 vitesses 2A

.
RTRDU 2 Auto-transformateur - Systemair
N° article: 5945
RTRDU 2 Auto-transformateur

Auto-transformateur triphasé 2x5 vit. 2A

.
SG-315 Grille - Systemair
N° article: 5611
SG-315 Grille

Grille de protection Ø315mm

.
U-EK230E Protection Moteur EX - Systemair
N° article: 30199
U-EK230E Protection Moteur EX

Protection Moteur EX

.
REV-3POL ATEX 11kW-25A ON/OFF - Systemair
N° article: 36414
REV-3POL ATEX 11kW-25A ON/OFF

25A, IP66, 2NO, switch 0/1, red/ yellow

.
FK 315 Manchette - Systemair
N° article: 1613
FK 315 Manchette

Manchette de raccordement circulaire Ø315mm

.
Ex e-Terminal box 1,5/6mm² 32A - Systemair
N° article: 2704
Ex e-Terminal box 1,5/6mm² 32A

115x115x64mm, 690V, 1,5/6m³, 32A, IP66

.