AXCBF 400D4-32

Axial fan, 200°C continuous temperature

N° article: 32483

Axial fan of the AXCBF series, suitable for continuous operation in temperatures between -20°C and 200°C. CE mark of conformity.

 

Impeller:

- The adjustable blade angle allows flexible and exact adjustment to the desired working point with optimum efficiency. The blade angle is pre-set in the factory.

- Impellers with profiled blades made of cast aluminum alloy.

- Dynamically balanced according to ISO 21940-11 and ISO 14694, balancing quality G6,3.

 

Casing:

- Manufactured from hot-dip galvanized sheet steel according to ISO 1461.

- Pre-drilled, rolled Eurovent 1/2 flanges pressed on both sides provide additional stability.

 

Motor:

- High efficiency three-phase asynchronous motors with squirrel cage rotor.

- Protection class IP55 (IEC 60034-5), insulation class F.

- The motors are equipped with PTC thermistors for motor protection.

- Motor is outside of the airstream.

- Speed controllable via frequency converter, suitable for turn down to 10Hz.

 

The AXCBF axial fans have been tested in Systemair’s AMCA certified Laboratory according to ISO 5801 and AMCA 210.

 

Paramètres techniques

Données nominales
Tension (nominale) 400 V
Fréquence 50 Hz
Phases 3~
Connexion moteiur D; Y
Puissance installée 348 W
Puissance nominale à l'axe (P2) 0,55 kW
Intensité 1,5 A
Vitesse de rotation 1 460 tr/min
Débit d'air max 3 622 m³/h
Température air en mouvement max 200 °C
Données acoustiques
Pression sonore à 1 m 80 dB(A)
Protection/Classification
Indice de protection, moteur IP55
Classe d'isolation F
Plage de température, ambiante et conduit
Température ambiante max 55 °C
Dimensions et poids
Conduit Circul d'aspiration 400 mm
Conduit Circul de refoulement 400 mm
Poids 45,1 kg
Autres
Type de connexion Circulaire
Type de moteur AC

 

 

Mid-frequency band, Hz

 

Hz Tot 63 125 250 500 1k 2K 4K 8K

LwA inlet /outlet

dB(A)

80

52

62

71

75

76

73

69

61

Measuring point: qv = 0,7 m3/s, Ps = 127 Pa

Images Dimensions - AXCBF 400D4-32 - Systemair
A Ø B Ø C Ø D Ø F G Ø H I

AXCBF 400

625

585

400

480

450

22,5°

12

8 x 45°

RFA
DXF

Axial fan of the AXCBF series, suitable for continuous operation in temperatures between -20°C and 200°C. CE mark of conformity.

 

Impeller:

Impellers with profiled blades made of cast aluminum alloy.

Dynamically balanced according to ISO 21940-11 and ISO 14694, balancing quality G6,3

 

Casing:

Manufactured from hot-dip galvanized sheet steel according to ISO 1461.

Pre-drilled, rolled Eurovent 1/2 flanges pressed on both sides.

 

Motor:

High efficiency three-phase motors.

Protection class IP55 (IEC 60034-5), insulation class F.

The motors are equipped with PTC thermistors for motor protection.

Motor is outside of the airstream.

Speed controllable via frequency converter.

 

 

 

 

EVH 400 Rac. flex.AXC 400°C - Systemair
N° article: 8366
EVH 400 Rac. flex.AXC 400°C

Raccord flexible 400°C avec brides

.
FRQ-4A V2 - Systemair
N° article: 36227
FRQ-4A V2

208-480V, 3~, 4A, IP54, 0-10V

.
FRQ5-4A+LED V2 - Systemair
N° article: 36229
FRQ5-4A+LED V2

208-480V, 3~, 4A, IP54, 5 steps, LED

.
FRQ5S-4A+LED V2 Variateur - Systemair
N° article: 36233
FRQ5S-4A+LED V2 Variateur

Variateur de fréquence 5 vitesses - 4A

.
FRQS-4A V2 Variateur - Systemair
N° article: 36231
FRQS-4A V2 Variateur

Variateur de fréquence 0-10V extérieur - 4A

.
FSD1 AXC Amortisseurs ≤ 64kg - Systemair
N° article: 311438
FSD1 AXC Amortisseurs ≤ 64kg

Jeu de 4 plots ressort

.
GFL-AR/AXC 400 Contre-bride - Systemair
N° article: 8378
GFL-AR/AXC 400 Contre-bride

Contre-bride pour ventilateur axial AR et AXC

.
LRK 400(F) Clapet anti-retour - Systemair
N° article: 8318
LRK 400(F) Clapet anti-retour

Clapet anti-retour F400-120 pour AXC

.
MFA-AXCBF 400 Console montage - Systemair
N° article: 308726
MFA-AXCBF 400 Console montage

hf=315mm, 1 pc., for air handling units

.
RSA 400/400/070 (F) - Systemair
N° article: 311352
RSA 400/400/070 (F)

Piège à son F400-120

.
RSA 400/600/070 (F) - Systemair
N° article: 311353
RSA 400/600/070 (F)

Piège à son F400-120

.
RSA 400/800/070 (F) - Systemair
N° article: 311354
RSA 400/800/070 (F)

Piège à son F400-120

.
SG AXC/AM/AR 400 Grille Protec - Systemair
N° article: 310687
SG AXC/AM/AR 400 Grille Protec

Grille de protection

.
U-EK230E Protection Moteur EX - Systemair
N° article: 30199
U-EK230E Protection Moteur EX

Protection Moteur EX

.
FC102-1,1kW/3A-IP55, 150/50m - Systemair
N° article: 36158
FC102-1,1kW/3A-IP55, 150/50m

Variateur de fréquence TRI

.
REV-5POL/07-7,5kW B/G - Systemair
N° article: 281742
REV-5POL/07-7,5kW B/G

16A, IP66, 1NC, switch 0/1+mounting kit, black/grey

.