Ce produit n'est plus disponible ou a été remplacé.

X-Topvex SX06 EL-R AHU-C

Numéro article: 25975

Low energy use

 - Energy efficient plug fans with EC motors 

Plug and play

 - Integrated control system

 - Pre-configured

Easy to operate

 - Menu based controller

Factory tested

Ready for demand controlling

Step-less and individual fan speed settings

Easy maintenance

Manufactured in Aluzinc

Topvex SX is an air handling unit with a modern design intended for ventilating offices, day-care centres or used as zone ventilation in larger buildings e.g. schools.

Topvex SX is equipped with EC fan motors. EC-motors consume an average of 30 % less energy than standard alternating current motors. In some applications, the saving can be 50 % or more.

Topvex SX with its crossflow heat exchanger is normally used where it is a requirement that the supply and exhaust air must be kept separated. The unit has an efficient de-icing function.

Ice accretion of the heat exchanger is depending on the outdoor temperature and the humidity in the extract air. The humidity in the extract air is varying a lot depending on what activities it is in the building e.g. an industry premises is normally producing much less humidity than a day-care centre. Therefore has the de-icing function been made settable so that it can be optimized to different applications.

The housing is made of insulated panels and has bevelled cast aluminium corners to avoid sharp edges. Doors and panels are made of double-skinned 0.9mm aluzink with 50mm of internal mineral insulation. Main components are removable with quick release connections for the electrical cables and the large inspection doors facilitate inspection and servicing.

Topvex SX is delivered complete with control system, supply and extract filter, cross flow heat exchanger, by-pass damper and Electrical or Hot water heater.

Topvex SX is as standard equipped with the following communication possibilities: Exoline and Modbus via RS-485, a built-in WEB server via TCP/IP and BACnet/IP.

The unit is ready configured and therefore very easy to set up, set the Time and date, desired air temperature, fan speed (0-100%), weekly operating time and the unit is up-and-running.

The units have energy saving functions like:

- Cool recovering to recover the chilliness in the extract air, when using an

external cooling unit.

- Demand controlled airflow by using a digital CO2/ humidity sensor or a movement

detector.

- Sum alarm output

Paramètres techniques

Unité
Fréquence 50 Hz
Tension nominale 400 V
Phase(s) [~] 3N~
Fusible recommandé 3x32 A
Indice de protection IP23
Variateur Réglable en continu
Ventilateur de soufflage
Puissance installée (P1), Vent. Soufflage 1 052 W
Filtre soufflage
Classe de filtration; air soufflé F7
Filtre extraction
Classe de filtration; air extrait F5
Echangeur de chaleur
Type d'échangeur Flux croisés
Chauffage
Type de chauffage Électrique TEST
Puissance installée; Batt. Chauf 14 kW
Ventilateur d'extraction
Puissance installée; Ventilateur extraction 1 052 W
Autres
Taille de chassis 06
Lieu d'installation Horizontal
Côté soufflage Droite
Dimensions et poids
Poids 272 kg
BFT SX06 ePM1 60% Filtre - Systemair Numéro article: 206188 BFT SX06 ePM1 60% Filtre .
BFT SX06 ePM10 60% Filtre - Systemair Numéro article: 206187 BFT SX06 ePM10 60% Filtre .
CVVX 500 Combi grille, black - Systemair Numéro article: 6237 CVVX 500 Combi grille, black .
DS 60-30 Manchette - Systemair Numéro article: 1547 DS 60-30 Manchette .
EFD 60-30 Registre TF24 - Systemair Numéro article: 6906 EFD 60-30 Registre TF24 .
F-T120 - Systemair Numéro article: 5137 F-T120 .
IR24-PC Détecteur de présence - Systemair Numéro article: 7288 IR24-PC Détecteur de présence .
LDR 60-30 Silencieux - Systemair Numéro article: 5072 LDR 60-30 Silencieux .
LDR-B 60-30 Silencieux - Systemair Numéro article: 9240 LDR-B 60-30 Silencieux .
PGDX-DXRE 600x350-3-2,5 Batt. - Systemair Numéro article: 7956 PGDX-DXRE 600x350-3-2,5 Batt. .
PGK 600x350-3-2,0 Batterie - Systemair Numéro article: 6612 PGK 600x350-3-2,0 Batterie .
Push button, impulse - Systemair Numéro article: 9693 Push button, impulse .
Siphon à boule - Systemair Numéro article: 206263 Siphon à boule .
T 120 - Systemair Numéro article: 5165 T 120 .
TG-R5/PT1000 Sonde - Systemair Numéro article: 5404 TG-R5/PT1000 Sonde .
TG-UH/PT1000 Sonde - Systemair Numéro article: 35203 TG-UH/PT1000 Sonde .
UG3-A4O Smoke detector - Systemair Numéro article: 15043 UG3-A4O Smoke detector .