Airflow Horizontal Water refrigerated
Art. no.: 369048
Application
R series close control air conditioners are built and sized in such a way that they can be installed alongside data center racks in air conditioning systems for large data centers.
Technical features
• 2 sizes
• Cooling capacity from 25 to 38 [kW]
• Chilled water circuit
• G4/G2-class efficiency air filters with dirty filter alert
• EC electric brushless plug fans
• Power supply 400V/3pH/50Hz
Standard features
• Very high EER
• SySmart control microprocessor with graphic display
• Electrical panel complete with control and safety devices
• Cooling, electric and water top/bottom connections
• Supply and return air temperature sensors
• Unit shutdown system for the presence of fire
• RS485 and RJ45 ports for Modbus® RTU and TCP/IP
• Panels with thermo-acoustic insulation
• Front and rear accessibility for easy maintenance
• Limited footprint
Available accessories for chilled water units
• Two-way control valves
• Inlet and outlet water temperature sensors
• HT Kit for operation at high condensing temperatures
Humidification
• Room humidity probe
• Supply humidity probe
• Immersed electrodes humidifier
Mechanical and structural
• Condensate drain pump
• G4/M5 efficiency class intake air filter (EU5) (depending on size)
• Closed front panel for side supply
• Closed side panels for front supply
• Wheels for handling
Electrical
• Alternative voltages available 460V/3ph/60Hz - 380V/3ph/60Hz - 230V/3ph/60Hz
• Electrical supply line without neutral
• Automatic transfer switch (ATS), Basic version
• Automatic transfer switch (ATS), Advanced version
Regulation
• Constant air flow and pressure control
• Local network set up and connection cable
• User terminal for remote installation
• Flooding detection system
Dimensions and weights | ||
---|---|---|
Weight | 0 | kg |
Model | ST HRU 20 | ST HRU 40 |
Width, mm |
1200 |
1222 |
Depth, mm |
300 |
600 |
Height, mm |
1975 |
1985 |
Type of circuit |
Chilled water |
Chilled water |
Inlet connections |
F Ø 1"1/4 G |
F Ø 1"1/4 G |
Outlet connections |
F Ø 1"1/4 G |
F Ø 1"1/4 G |
Document filename | Document filetype | |
---|---|---|
SYSTEMP brochure | Brochure | |
SYSTEMP - Engineering Data Manual (EDM SYSTEMP-S-7GB) | Manual | |
SYSTEMP – Installation Operation Manual (IOM SYSTEMP-rev.N) | Manual | |
ST UP211_50B.DWG | CAD-file | |
ST UP301_372B.DWG | CAD-file | |
ST UP361_110B.dwg | CAD-file | |
ST UP491_852B.DWG | CAD-file | |
ST UP932_160B.dwg | CAD-file | |
TUP71_20B.dwg | CAD-file |