Genius complete unit

Art. no.: 84349

The building service centre efficiently and economically combines the complete building equipment for energy efficient single-family houses. It unifies the functions heating, cooling, ventilation, heat recovery and hot water.

Controlled room ventilation with integrated heat recovery provides a balanced and agreeable indoor climate.

The room ventilation is completed by a steplessly controlled air/air/water-heat pump which acts as a pure air heating in winter and provides the cooling of the house - by reversible operations - in summer.

 

The heat pump adjusts its performance according to the requirements for a highly efficient operation.

Moreover, the combi unit is equipped with a 150 litres drinking water reservoir and ensures by a parallel mode in the heating as well as in the cooling mode a high water comfort.

The system is controllable by an internet application or via control panel on the unit. In addition an intelligent single room control via room sensors is possible.

Further advantages of the combi unit are the emergency mode for heating as well as for hot water, the fast charging hot water and the thermally isolated ventilation unit.

In combination with PV systems it is possible to conceive self-sufficient and CO2 neutral systems.

 

 

Energy class label

Energy class, Local demand
Material Declaration, BVB, Acceptable 0
Material Declaration, Sunda Hus, Level A or B 0
EPD 0

Technical parameters

Product
Voltage (nominal) 230 V
Frequency 50 Hz
Input power, compressor (at 60 rps) 1,140 W
Input power, max, fan heat pump module 170 W
Input power, max, fan ventilation module (each) 80 W
Input power, charging pump 28 W
Air flow (normal mode at 100Pa) 180 m³/h
Max. air flow heating/cooling (incl. secondary air) 600 m³/h
Weight, heat pump module 60 kg
Weight, hot water module 170 kg
Total weight, empty 305 kg
Total weight, filled 460 kg
Weight, ventilation module 75 kg
Exchanger
Maximum heat recovery 88 %
Filter
Filter class, extract air G4
Filter class, secondary air G4
Filter class, outdoor air F7
Dimensions and weights
Width 865 mm
Height 2,070 mm
Depth 750 mm
Weight 370.9 kg
Connections
Chilled water (connection size) 1" AG
Hot water (connection size) 1" AG
Circulation (connection size) 1"
Condensate (hose connection, 5x) 10 mm
Safety valve (hose connection) 3/4"
Other
Refrigerant R410A
Weight, filling quantity refrigerant 1.2 kg
Volume, storage content 150 L
Volume, expansion tank 6 L
Safety valve, hot water 0.6 MPa
Images Performance - Genius complete unit - Systemair

 

Performance 1 Performance 2 Performance 3 Unit

Heating power, PTC-elements (each)

500

500

500

W

Heating power, heater rod WW

3

3

3

kW

Heating pump

60

60

40

%

Temperature, outdoor air

-3

10

10

°C

Temperature, supply air

41,8

43,4

38

°C

Heat recovery efficiency total unit (fictive)

253

399

301

%

Performance rating (COP) total unit

6,39

5,99

9,03

COP

Volume related electr. compressor capacity

4,63

4,52

1,16

W/(m³/h)

Electric efficiency ratio

5,9

5,44

7,74

Heating capacity

6000

6000

6000

W

Cooling capacity

4000

4000

4000

W

Setpoint air flow

120

125

200

m³/s

Temperature, extract air

21

21

21

°C

Volume related electr. ventilation capacity

0,73

1,11

1,16

W/(m³/h)

Images Dimensions - Genius complete unit - Systemair
.

 

 

Building Services Central Genius

Reversible air-air/air-water heatpump for heating, cooling (air-air) and hot water (air-water). Ventilation and heat recovery by rotating heat exchangers. Includes pre-wired control box.Modular design with the modules of hot water, heat pump and ventilation.

Module ventilation with supply-, extract and secondary air fan, rotary heat exchanger as well as outside air, extract air and secondary air filters. Supply air with F7 pollen filter, extract- and secondary air with F5 cassette filter . Filter monitoring using filter life.Rotary heat exchanger with heat and moisture transfer. Heat recovery rate to 85%.Casing made of double-skinned galvanized sheet steel with 30mm mineral wool for thermal and acoustic insulation. Secondary air and supply air have a diameter of 200mm, outside and extract air 160mm.The fans are energy efficient EC radial fans with a maximum power consumption of 80 Watts each.Flow-related application without secondary air operation 100 to 250m ³ / h, with secondary air operation to max.600m ³ / h (100 Pa) at 100% power requirement of the heat pump.Requires no frost protection, as the rotary heat exchanger fed the condensate produced in the winter into the supply air (automatic humidification of the air). Any condensate of the secondary air chamber comes into the heat pump module, where it is derived.

 

Module heating / cooling / hot water with modulating heat pump, reversible by use both for heating and cooling as well as hot water.R410A refrigerant.

 

Secondary air fan is activated in parallel with compressor. Power output by increasing the airflow. Heat to the secondary air (condenser in heating mode) or heat from the working fluid air (evaporator in heating mode) by two air lamella heat exchangers in the cooling circuit. A 0-10V driven modulating radial fan provides the necessary care during the heating of the working fluid and air safe during cooling operation of the heat transport. Exhaust air from the fan module is introduced into the suction area of the working air, to raise the swelling temperature.Heating capacity up to 6 kW cooling capacity up to 4 kW.

 

Hot water production by the hot gas line built, permanently flown through a plate heat exchanger. This preparation also operates parallel with heating / cooling. Heat transport on demand using high-efficiency pump. DHW storage150l,enameled, with a sacrificial anode. Electrical coil, 3 kW, integrated.

 

Control over display or primarily on the Internet through a direct or indirect connection to the PC. Website with user and service level, all parameters readable or adjustable.

- 4 ventilation levels according to DIN 1946/6- Room temperatures- Quick charge, legionella control, emergency hot water- Individual room temperature control, emergency heating by PTC elements- Outdoor compensated room-temperature setpoint adjustment winter and summer, alternatively manually- Outdoor temperature compensated shift of max. supply air temperature, alternatively manually- Min supply air temperature summer- Time programs, nightmode- DHW bivalence point- Filter alarm- Passive night cooling, adjustable- Fan speed (balance commissioning)

 

Roomcontroller as accessories, max. 6 pieces. Mandatory.PTC-heating elements as accessories, power per 500W.

 

Systemair-E CO2 sensor - Systemair
Art. no.: 14904
Systemair-E CO2 sensor

14904 Systemair-E CO2 sensor

.
Systemair-E-D CO2 sensor - Systemair
Art. no.: 14905
Systemair-E-D CO2 sensor

14905 Systemair-E-D CO2 sensor

.
TG-K360 Duct sensor 0-60°C - Systemair
Art. no.: 4846
TG-K360 Duct sensor 0-60°C

for heating regulator HRG

.
CBM 160-2,1 230V/1 Duct heater - Systemair
Art. no.: 5482
CBM 160-2,1 230V/1 Duct heater .
CBM 200-3,0 230V/1 Duct heater - Systemair
Art. no.: 7593
CBM 200-3,0 230V/1 Duct heater .
Argus-RC-C3DOC Room controller - Systemair
Art. no.: 27142
Argus-RC-C3DOC Room controller

Room Controller with Modbus communication

.
Argus-RC-CDO Room controller - Systemair
Art. no.: 2994
Argus-RC-CDO Room controller

Room controllers with Modbus communication

.
Connectduct Ø 160/1,0 M/F - Systemair
Art. no.: 2558
Connectduct Ø 160/1,0 M/F .
Connectduct Ø 200/1,0 M/F - Systemair
Art. no.: 2560
Connectduct Ø 200/1,0 M/F .
Genius Modul PTC heating elem. - Systemair
Art. no.: 312784
Genius Modul PTC heating elem. .
PF Genius STD kit - Systemair
Art. no.: 318112
PF Genius STD kit

PF kit=3pcs(F7/ePM1 60% sup and G4/Coarse65% ext/secondary)

.
SCD 160 silencer 50mm insulat. - Systemair
Art. no.: 84332
SCD 160 silencer 50mm insulat.

Silencer with 50mm insulation M/F

.
SCD 250 silencer 50mm insulat. - Systemair
Art. no.: 87545
SCD 250 silencer 50mm insulat.

Silencer with 50mm insulation M/F

.