BF 100 QW Bathroom fan

Bathroom fan <125W

Art. no.: 254516

Ideal for extraction of air in bathroom, toilet and small/medium premises. Suitable to extract stale air directly to the outside or through short length ducting.

Units can be wall/panel, ceiling and window mounted.

Casing made of high quality ABS provides long lasting shock-proof and robust construction. The unit is finished in white RAL 9010 and are UV resistant.

Unique design winglet type impeller, providing enhanced aerodynamic properties, low noise and increased efficiency.

Single phase induction motors with integral thermal protection, mounted on sealed for life high quality sleeve bearings.

Suitable for continuous and intermittent running.

Ecodesign

Ecodesign
ErP compliance 2018
Unit category RVU
Drive External MSD or VSD
Unit type UVU
Heat recovery type None
Temperature ratio (UVU) Not applicable
qv nom 0.0151 m³/s
P nom 0.01 kW
Ps nom 12 Pa
Fan efficiency 1.7 %
Basic unit
ErP compliance 2018
SEC Average -8.59 kWh/(m².a)
SEC Cold -24.99 kWh/(m².a)
SEC Warm 0.8 kWh/(m².a)
SEC Class F
Unit category RVU
Unit type UVU
Drive External MSD or VSD
Heat recovery type None
Temperature ratio (UVU) Not applicable
qv max 54 m³/h
P max 10 W
qv ref 0.0106 m³/s
Ps ref 50 Pa
SPI 0.273 W/(m³/h)
CTRL 1
MISC 1.1
x-value 1.5
External Leakage Not applicable
AEC average 342 kWh
AHS Cold 342 kWh
AEC warm 342 kWh
AHS Average 17 kWh/a
AHS Cold 34 kWh/a
AHS Warm 8 kWh/a
Units with local demand control
ErP compliance 2018
SEC Average -32.81 kWh/(m².a)
SEC Cold -50.88 kWh/(m².a)
SEC Warm -8.31 kWh/(m².a)
SEC Class C
Unit category RVU
Unit type UVU
Drive External MSD or VSD
Heat recovery type None
Temperature ratio (UVU) Not applicable
qv max 54 m³/h
P max 10 W
qv ref 0.0106 m³/s
Ps ref 50 Pa
SPI 0.273 W/(m³/h)
CTRL 0.65
MISC 1.1
x-value 1.5
External Leakage Not applicable
AEC average 179 kWh
AEC cold 179 kWh
AEC warm 179 kWh
AHS Average 28 kWh/a
AHS Cold 55 kWh/a
AHS Warm 13 kWh/a

Technical parameters

Nominal data
Voltage (nominal) 230 V
Frequency 50 Hz
Phases 1~
Input power 11 W
Input current 0.069 A
Impeller speed 2,230 rpm
Air flow max 78 m³/h
Temperature of transported air max 50 °C
Sound data
Sound pressure level at 3m (free field) 33 dB(A)
Protection/Classification
Enclosure class, motor IPX4
Insulation class B
Data according to ErP
Energy class, Basic unit C
Energy class, Local demand F
ErP ready ErP 2018
Dimensions and weights
Duct dimension; Circular, inlet 100 mm
Weight 0.81 kg
Others
Motor type AC