Bathroom fan <125W
Art. no.: 254516
Ideal for extraction of air in bathroom, toilet and small/medium premises. Suitable to extract stale air directly to the outside or through short length ducting.
Units can be wall/panel, ceiling and window mounted.
Casing made of high quality ABS provides long lasting shock-proof and robust construction. The unit is finished in white RAL 9010 and are UV resistant.
Unique design winglet type impeller, providing enhanced aerodynamic properties, low noise and increased efficiency.
Single phase induction motors with integral thermal protection, mounted on sealed for life high quality sleeve bearings.
Suitable for continuous and intermittent running.
Ecodesign | ||
---|---|---|
ErP compliance | 2018 | |
Unit category | RVU | |
Drive | External MSD or VSD | |
Unit type | UVU | |
Heat recovery type | None | |
Temperature ratio (UVU) | Not applicable | |
qv nom | 0.0151 | m³/s |
P nom | 0.01 | kW |
Ps nom | 12 | Pa |
Fan efficiency | 1.7 | % |
Basic unit | ||
---|---|---|
ErP compliance | 2018 | |
SEC Average | -8.59 | kWh/(m².a) |
SEC Cold | -24.99 | kWh/(m².a) |
SEC Warm | 0.8 | kWh/(m².a) |
SEC Class | F | |
Unit category | RVU | |
Unit type | UVU | |
Drive | External MSD or VSD | |
Heat recovery type | None | |
Temperature ratio (UVU) | Not applicable | |
qv max | 54 | m³/h |
P max | 10 | W |
qv ref | 0.0106 | m³/s |
Ps ref | 50 | Pa |
SPI | 0.273 | W/(m³/h) |
CTRL | 1 | |
MISC | 1.1 | |
x-value | 1.5 | |
External Leakage | Not applicable | |
AEC average | 342 | kWh |
AHS Cold | 342 | kWh |
AEC warm | 342 | kWh |
AHS Average | 17 | kWh/a |
AHS Cold | 34 | kWh/a |
AHS Warm | 8 | kWh/a |
Units with local demand control | ||
---|---|---|
ErP compliance | 2018 | |
SEC Average | -32.81 | kWh/(m².a) |
SEC Cold | -50.88 | kWh/(m².a) |
SEC Warm | -8.31 | kWh/(m².a) |
SEC Class | C | |
Unit category | RVU | |
Unit type | UVU | |
Drive | External MSD or VSD | |
Heat recovery type | None | |
Temperature ratio (UVU) | Not applicable | |
qv max | 54 | m³/h |
P max | 10 | W |
qv ref | 0.0106 | m³/s |
Ps ref | 50 | Pa |
SPI | 0.273 | W/(m³/h) |
CTRL | 0.65 | |
MISC | 1.1 | |
x-value | 1.5 | |
External Leakage | Not applicable | |
AEC average | 179 | kWh |
AEC cold | 179 | kWh |
AEC warm | 179 | kWh |
AHS Average | 28 | kWh/a |
AHS Cold | 55 | kWh/a |
AHS Warm | 13 | kWh/a |
Nominal data | ||
---|---|---|
Voltage (nominal) | 230 | V |
Frequency | 50 | Hz |
Phases | 1~ | |
Input power | 11 | W |
Input current | 0.069 | A |
Impeller speed | 2,230 | rpm |
Air flow | max 78 | m³/h |
Temperature of transported air | max 50 | °C |
Sound data | ||
---|---|---|
Sound pressure level at 3m (free field) | 33 | dB(A) |
Protection/Classification | ||
---|---|---|
Enclosure class, motor | IPX4 | |
Insulation class | B |
Data according to ErP | ||
---|---|---|
Energy class, Basic unit | C | |
Energy class, Local demand | F | |
ErP ready | ErP 2018 |
Dimensions and weights | ||
---|---|---|
Duct dimension; Circular, inlet | 100 | mm |
Weight | 0.81 | kg |
Others | ||
---|---|---|
Motor type | AC |
Document filename | Document filetype | |
---|---|---|
INSTALLATION_MANUAL_BF_QW_MULTILINGUAL.PDF | Manual | |
BF_QW_SYSTEMAIR_20221025_150816655.PDF | Technical Data sheets | |
BVB_BF_QW_SYSTEMAIR_EN.PDF | Declaration |