Art. no.: 1254
The RVF models are exhaust-air fans for installation on external walls. The unit consists of an impeller with backward-curved blades and a casing in galvanised sheet steel with a white powder-paint coating. All ambient noise created by the fan is kept outside the building if it is installed on an external wall.
Product | ||
---|---|---|
Trade name | Systemair | |
Product name | RVF 100 M Wall fan |
Basic unit | ||
---|---|---|
ErP compliance | 2018 | |
SEC Average | -8 | kWh/(m².a) |
SEC Cold | -24.4 | kWh/(m².a) |
SEC Warm | 1.4 | kWh/(m².a) |
SEC Class | F | |
Unit category | RVU | |
Unit type | UVU | |
Drive | External MSD or VSD | |
Heat recovery type | None | |
Temperature ratio (UVU) | Not applicable | |
qv max | 90 | m³/h |
P max | 27 | W |
Sound power level LWA | 47 | dB(A) |
qv ref | 0.018 | m³/s |
Ps ref | 50 | Pa |
SPI | 0.292 | W/(m³/h) |
CTRL | 1 | |
MISC | 1.1 | |
x-value | 1.5 | |
External Leakage | 0 | % |
AEC average | 365.9 | kWh |
AHS Cold | 365.9 | kWh |
AEC warm | 365.9 | kWh |
AHS Average | 1,715.2 | kWh/a |
AHS Cold | 3,355.3 | kWh/a |
AHS Warm | 775.6 | kWh/a |
Units with local demand control | ||
---|---|---|
ErP compliance | 2018 | |
SEC Average | -23.5 | kWh/(m².a) |
SEC Cold | -50.6 | kWh/(m².a) |
SEC Warm | -8 | kWh/(m².a) |
SEC Class | C | |
Unit category | RVU | |
Unit type | UVU | |
Drive | External MSD or VSD | |
Heat recovery type | None | |
Temperature ratio (UVU) | Not applicable | |
qv max | 92 | m³/h |
P max | 27 | W |
Sound power level LWA | 47 | dB(A) |
qv ref | 0.0178 | m³/s |
Ps ref | 50 | Pa |
SPI | 0.292 | W/(m³/h) |
CTRL | 0.65 | |
MISC | 1.1 | |
x-value | 1.5 | |
External Leakage | 0 | % |
AEC average | 191.8 | kWh |
AEC cold | 191.8 | kWh |
AEC warm | 191.8 | kWh |
AHS Average | 2,830 | kWh/a |
AHS Cold | 5,536.2 | kWh/a |
AHS Warm | 1,279.7 | kWh/a |
Energy class, Basic unit | ||
---|---|---|
Energy class, Local demand | ||
---|---|---|
Nominal data | ||
---|---|---|
Voltage (nominal) | 230 | V |
Frequency | 50 | Hz |
Phase(s) | 1~ | |
Input power | 28 | W |
Input current | 0.161 | A |
Impeller speed | 2,489 | rpm |
Air flow | max 200 | m³/h |
Temperature of transported air | max 70 | °C |
Max temperature of transported air, when speed controlled | 70 | °C |
Sound data | ||
---|---|---|
Sound pressure level at 10m (free field) | 26 | dB(A) |
Protection/Classification | ||
---|---|---|
Enclosure class, motor | IP44 | |
Insulation class | B |
Data according to ErP | ||
---|---|---|
Energy class, Basic unit | F | |
Energy class, Local demand | C | |
ErP ready | ErP 2016; ErP 2018 |
Dimensions and weights | ||
---|---|---|
Duct dimension; Circular, inlet | 100 | mm |
Duct dimension; Circular, outlet | 100 | mm |
Weight | 3.5 | kg |
Others | ||
---|---|---|
Duct connection type | Circular | |
Motor type | AC |
A | B | C | D | E | F | G | ||||
RVF 100 |
255 |
333 |
100 |
92,7 |
311,3 |
152 |
32 |
|||