Smoke extract axial fan AXC(B):

⁻ Certified according to EN 12101-3:2015 for 300°C/120 min.

⁻ CE mark of conformity by BSI.

⁻ Suitable for use inside or outside the fire zone. Temperature of medium for continuous operation from -20°C up to 55°C. Air direction from motor to impeller.

Impeller:

⁻ The adjustable blade angle allows flexible and exact adjustment to the desired working point with optimum efficiency.

⁻ Impellers with profiled blades made of cast aluminum alloy.

⁻ Dynamically balanced according to ISO 21940-11 and ISO 14694, balancing quality G6,3.

Casing:

⁻ Manufactured from hot-dip galvanized sheet steel according to ISO 1461.

⁻ Pre-drilled, rolled Eurovent 1/2 flanges pressed on both sides provide additional stability.

⁻ Pre-wired terminal box on fan casing for easy electrical connection, IP65 (IEC 60034-5).

⁻ PV version: Includes bolt-on outlet guide vanes which increases fan pressure and efficiency.

Motor:

⁻ Motor suitable for 300°C/120min or 55°C continuous operation.

⁻ High efficiency three-phase asynchronous motors with squirrel cage rotor, directly in the air stream.

⁻ Protection class IP55 (IEC 60034-5), insulation class H.

⁻ The motors can be equipped with PTC thermistors for motor protection (on request).

⁻ Single and two-speed motors are available.

⁻ Speed controllable via frequency converter, suitable for turn down to 10Hz.

The AXC(B) axial fans have been tested in Systemair’s AMCA accreditied Laboratory according to ISO 5801 and AMCA 210.

Technical parameters

Nominal data
Voltage (nominal) 400 V
Frequency 50 Hz
Phase(s) 3~
Maximum current 5.86 A
Impeller speed 2,891 rpm
Max. Temperature of transported air for 120 min 300 °C
Temperature of transported air max 55 °C
Protection/Classification
Enclosure class, motor IP55
Insulation class F
Controller and Sensors
Permitted ambient temperature max 55 °C
Max. Power load 3,000 W
Dimensions and weights
Weight 57 kg
Others
Motor type AC