RVF 100 M Wall fan

Art. no.: 1254

• Speed-controllable
• For mounting on external walls
• Useful where internal space is limited

The RVF models are exhaust-air fans for installation on external walls. The unit consists of an impeller with backward-curved blades and a casing in galvanised sheet steel with a white powder-paint coating. All ambient noise created by the fan is kept outside the building if it is installed on an external wall.

Ecodesign

Product
Trade name Systemair
Product name RVF 100 M Wall fan
Basic unit
ErP compliance 2018
SEC Average -8 kWh/(m².a)
SEC Cold -24.4 kWh/(m².a)
SEC Warm 1.4 kWh/(m².a)
SEC Class F
Unit category RVU
Unit type UVU
Drive External MSD or VSD
Heat recovery type None
Temperature ratio (UVU) Not applicable
qv max 90 m³/h
P max 27 W
Sound power level LWA 47 dB(A)
qv ref 0.018 m³/s
Ps ref 50 Pa
SPI 0.292 W/(m³/h)
CTRL 1
MISC 1.1
x-value 1.5
External Leakage 0 %
AEC average 365.9 kWh
AHS Cold 365.9 kWh
AEC warm 365.9 kWh
AHS Average 1,715.2 kWh/a
AHS Cold 3,355.3 kWh/a
AHS Warm 775.6 kWh/a
Units with local demand control
ErP compliance 2018
SEC Average -23.5 kWh/(m².a)
SEC Cold -50.6 kWh/(m².a)
SEC Warm -8 kWh/(m².a)
SEC Class C
Unit category RVU
Unit type UVU
Drive External MSD or VSD
Heat recovery type None
Temperature ratio (UVU) Not applicable
qv max 92 m³/h
P max 27 W
Sound power level LWA 47 dB(A)
qv ref 0.0178 m³/s
Ps ref 50 Pa
SPI 0.292 W/(m³/h)
CTRL 0.65
MISC 1.1
x-value 1.5
External Leakage 0 %
AEC average 191.8 kWh
AEC cold 191.8 kWh
AEC warm 191.8 kWh
AHS Average 2,830 kWh/a
AHS Cold 5,536.2 kWh/a
AHS Warm 1,279.7 kWh/a

Energy class label

Energy class, Basic unit
Energy class, Local demand

Technical parameters

Nominal data
Voltage (nominal) 230 V
Frequency 50 Hz
Phase(s) 1~
Input power 28 W
Input current 0.161 A
Impeller speed 2,489 rpm
Air flow max 56 L/s
Temperature of transported air max 70 °C
Max temperature of transported air, when speed controlled 70 °C
Sound data
Sound pressure level at 10m (free field) 26 dB(A)
Protection/Classification
Enclosure class, motor IP44
Insulation class B
Data according to ErP
Energy class, Basic unit F
Energy class, Local demand C
ErP ready ErP 2016; ErP 2018
Dimensions and weights
Duct dimension; Circular, inlet 100 mm
Duct dimension; Circular, outlet 100 mm
Weight 3.5 kg
Others
Duct connection type Circular
Motor type AC
A B C D E F G

RVF 100

255

333

100

92,7

311,3

152

32

RFA
DXF
RE 1,5 Speed control - Systemair
Art. no.: 5000
RE 1,5 Speed control .
REE 1 Speed control - Systemair
Art. no.: 5314
REE 1 Speed control .
REV-3POL/03 ON/OFF - Systemair
Art. no.: 33978
REV-3POL/03 ON/OFF .
SG 100 Protection guard - Systemair
Art. no.: 5606
SG 100 Protection guard .
CO2RT-R-D Transmitter - Systemair
Art. no.: 6993
CO2RT-R-D Transmitter .
DTV500A - Systemair
Art. no.: 96807
DTV500A .
HR1 Room Humidistat - Systemair
Art. no.: 215150
HR1 Room Humidistat .
Presence detector/IR24-P - Systemair
Art. no.: 6995
Presence detector/IR24-P .
RT 0-30 Room Thermostat - Systemair
Art. no.: 5151
RT 0-30 Room Thermostat .
Safety switch 2-pole grey - Systemair
Art. no.: 210679
Safety switch 2-pole grey .
T 120 Timer - Systemair
Art. no.: 5165
T 120 Timer .
RSK-100 Back draft damper - Systemair
Art. no.: 5597
RSK-100 Back draft damper .