TTC-2000 Temp. control 25A

Item Number: 5171

TTC2000 is a 3-phase triac controller for controlling electric heating up to 25 A. It is made for wall mounting. TTC2000 is to be connected in series between powersupply and an electric heater and can control both Y- and Delta- connected loads. TTC2000 can control assymetrical Delta-loads._x000D_

_x000D_

Function_x000D_

The controller pulses the entire power output ON/OFF. and utilises time-proportional control, the ratio between On-time and Off-time is varied to fit the prevailing heating requirement. E.g. ON = 30 sec. And OFF= 30 sec. gives 50% output power. The cycle-time (the sum of on-time and off-time) is adjustable 6...120 sec. _x000D_

_x000D_

TTC2000 automatically adapts control mode to suit the dynamics of the controlled object._x000D_

_x000D_

Supply air temperature control_x000D_

For rapid temperature changes, TTC2000 will work as a PI-controller with a fixed proportional band of 20K and a fixed reset time of 6 minutes._x000D_

_x000D_

Room temperature control_x000D_

For slow temperature changes, TTC2000 will work as a P-controller with a fixed proportional band of 1.5 K. When running room temperature control the supply air temperature can be maximum and/or minimum limited._x000D_

_x000D_

Controlling larger electric heaters_x000D_

At larger loads TTC2000 can be combined with ancillary board TT-S1

Technical parameters

Nominal data
Voltage (nominal) 230 V
Frequency 50 Hz
Phase(s) 3~
Input current 25 A
Temperature reduction at night 10 °C
Temperature adjustment 0 to 30 °C
Protection/Classification
Enclosure class IP30
Controller and Sensors
Permitted ambient temperature 0 to 40 °C
Dimensions and weights
Depth 94 mm
Height 207 mm
Width 160 mm
Weight 1.7 kg
TG-K330 Duct Sensor 0-30°C - Systemair
Item Number: 5160
TG-K330 Duct Sensor 0-30°C .
TG-K350 Duct Sensor 20-50°C - Systemair
Item Number: 5161
TG-K350 Duct Sensor 20-50°C .
TG-K360 Duct sensor 0-60°C - Systemair
Item Number: 4846
TG-K360 Duct sensor 0-60°C .
TG-R430 Room sensor 0-30°C - Systemair
Item Number: 5162
TG-R430 Room sensor 0-30°C .
TG-R530 Room sensor 0-30°C - Systemair
Item Number: 5163
TG-R530 Room sensor 0-30°C .
TG-R600 External sensor - Systemair
Item Number: 5174
TG-R600 External sensor .
TG-R630 External sensor - Systemair
Item Number: 5164
TG-R630 External sensor .
TT-S1(TT-SLAV) exp. module - Systemair
Item Number: 5173
TT-S1(TT-SLAV) exp. module .
TT-S4/D Step switching unit - Systemair
Item Number: 9154
TT-S4/D Step switching unit .