Αριθμός αντικειμένου: G1121
Geniox is designed to meet future energy requirements with high heat recovery efficiency and low power consumption. Each air handling unit function is placed into a casing module. The modular construction means that Geniox can be configured for many different applications to make up the heart of any ventilation system.
• Flexible design
• 60 mm panels, good thermal and sound insulation
• High air tightness
• Intelligent, easy to use control system
• Easy to select and install
• Eurovent Hygienic Air Handling Unit certified option
• VDI 6022-1 certified option
Geniox is available for indoor or outdoor installation in 16 sizes with airflows from 750-110,000 m3/h (0.2-30 m3/s). The air handling unit is available with or without Systemair Access control system or as Controller Ready, which means that you can connect your own controller.
The Access control system comes with the NaviPad control panel, which makes it quick and easy for you to monitor and adjust your indoor climate. You can also integrate Access into your Building Management System with Modbus or BACnet communication, or connect it to our cloud service Systemair Connect.
Geniox is available with rotary heat exchanger or run-around coil heat exchangers, cross flow heat exchanger or counter flow heat exchanger. For heating and cooling, you can choose coil media as water or refrigerant, and we also offer electric heating. Geniox is available in three colors: Dark grey (Zinc-magnesium galvanization) or pre-painted black or light grey.
Geniox air handling units are #HygienicByDesign. You can choose Geniox as Eurovent Hygienic Air Handling Unit certified or VDI 6022-1 certified. Systemair is the first major manufacturer worldwide to offer a Eurovent certified performance option for Hygienic Air Handling Units (HAHU) as a feature in all Geniox units. VDI 6022-1 is a set of guidelines for ventilation and indoor air quality in order to ensure healthy breathing air in buildings. Geniox air handling units undergo regular, third-party audits.
The environmental impact from Geniox has been reduced by using recyclable materials and creating solutions that can be adjusted for future requirements. With SystemairCAD, it is possible to calculate the Life Cycle Cost (LCC) to provide you with a complete overview of the financial environmental effects of choosing a Geniox air handling unit.
Geniox is delivered with all necessary documentation to help you assemble, set up and service the unit. Compact design and quick assembly shortens installation time and provides a cost effective installation.Geniox is certified by Eurovent. This means that the air handling unit undergoes third party tests to document that energy cost and design specifications are correctly stated.
Capacity and technical data are calculated by the software SystemairCAD. SystemairCAD can be downloaded via the link below.
Μονάδα | ||
---|---|---|
Κανονισμός ταχύτητας | Βηματικό | |
Παροχή αέρα | 750 110.000 | m³/h |
Ενναλάκτης | ||
---|---|---|
Εναλλάκτης θερμότητας | Περιστρεφόμενης, αντίρροπης ροής, διασταυρούμενης ροής ή στοιχείων νερού-νερού(run-around) |
Υπόλοιποι | ||
---|---|---|
Έλεγχος ανεμιστήρα | CAV, έλεγχος παροχής αέρα; Εξωτερική αντισταθμισμένη ροή αέρα; VAV, έλεγχος πίεσης | |
Τύπος εγκατάστασης | Οριζόντιος | |
Πλευρά προσαγωγής | Αριστερά; Δεξιά |
Διαστάσεις και βάρη | ||
---|---|---|
Βάρος | 0 | kg |
Green - Airflow range for Geniox complying with Ecodesign.
Gray - Full airflow range for Geniox.
Rotating heat exchanger |
||||||||||||||||
|
10 |
11 |
12 |
14 |
16 |
18 |
20 |
22 |
24 |
27 |
29 |
31 |
35 |
38 |
41 |
44 |
Width |
1082 |
1182 |
1282 |
1482 |
1682 |
1882 |
2082 |
2282 |
2482 |
2782 |
2982 |
3182 |
3482 |
3482 |
4082 |
4082 |
Height* |
1082 |
1182 |
1282 |
1482 |
1682 |
1882 |
2082 |
2282 |
2482 |
2764 |
2964 |
3164 |
4000 |
4600 |
4600 |
5200 |
Length |
2282 |
2282 |
2282 |
2282 |
2282 |
2282 |
2382 |
2382 |
2582 |
2782 |
2982 |
3182 |
4646 |
4646 |
4646 |
4646 |
The above dimensions and weights are a guideline only. Accurate values and combinations are calculated in SystemairCAD. |
||||||||||||||||
* Height excl. legs/base frame. |
Counter flow heat exchanger |
|||||||
|
10 |
11 |
12 |
14 |
16 |
18 |
20 |
Width |
1082 |
1182 |
1282 |
1482 |
1682 |
1882 |
2082 |
Height* |
1082 |
1182 |
1282 |
1482 |
1682 |
1882 |
2082 |
Length |
3182 |
3382 |
3382 |
3482 |
3782 |
3782 |
3982 |
The above dimensions and weights are a guideline only. Accurate values and combinations are calculated in SystemairCAD. |
|||||||
* Height excl. legs/base frame. |
Cross-flow exchanger |
|||||||||||||
|
10 |
11 |
12 |
14 |
16 |
18 |
20 |
22 |
24 |
27 |
29 |
31 |
35 |
Width |
1082 |
1182 |
1282 |
1482 |
1682 |
1882 |
2082 |
2282 |
2482 |
2782 |
2982 |
3182 |
3482 |
Height* |
1082 |
1182 |
1282 |
1482 |
1682 |
1882 |
2082 |
2282 |
2482 |
2764 |
2964 |
3164 |
4000 |
Length |
2982 |
3082 |
3182 |
3382 |
3582 |
3782 |
3782 |
4282 |
4582 |
4782 |
5282 |
5282 |
6946 |
The above dimensions and weights are a guideline only. Accurate values and combinations are calculated in SystemairCAD |
|||||||||||||
* Height excl. legs/base frame. |
Integrated reversible heat pump |
|||||||||
|
10 |
11 |
12 |
14 |
16 |
18 |
20 |
22 |
24 |
Width |
1082 |
1182 |
1282 |
1482 |
1682 |
1882 |
2082 |
2282 |
2482 |
Height* |
1082 |
1182 |
1282 |
1482 |
1682 |
1882 |
2082 |
2282 |
2482 |
Length |
3282 |
3282 |
3282 |
3282 |
3482 |
3482 |
4082 |
4182 |
4382 |
The above dimensions and weights are a guideline only. Accurate values and combinations are calculated in SystemairCAD. |
|||||||||
* Height excl. legs/base frame. |
Έγγραφο ονόματος αρχείου | Έγγραφο τύπου αρχείου | |
---|---|---|
Geniox Catalogue | Ενημερωτικό φυλλάδιο | |
Access 4x Εγχειρίδιο διαμόρφωσης (V4.1 B004) | Εγχειρίδιο | |
Access Operator's Guide | Εγχειρίδιο | |
Geniox user manual | Εγχειρίδιο | |
Geniox User Manual - Hygienic air handling unit | Εγχειρίδιο | |
Heat pump user manual | Εγχειρίδιο | |
Eurovent Certificate Geniox | Πιστοποίηση | |
Eurovent Certificate Geniox Hygienic.pdf | Πιστοποίηση | |
Geniox VDI certificate | Πιστοποίηση | |
Geniox VDI label | Πιστοποίηση | |
Commissioning Record | Εκκίνηση | |
DVU-HP Control system 31.01.07 | Καλωδίωση | |
GENIOX-DV CONTROL SYSTEM VERSION 11.04.08 | Καλωδίωση |